Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

TetraFuse: A Synergistic Four-Dimensional Dynamic Fusion Framework for Efficient and Robust Medical Image Classification

Created on 07 Jun 2026

Authors

Gao, Y., Li, J., Xu, J., Li, Q., Li, Z., Shi, Y., ZHao, G., Wu, X., Zhang, Y.

Abstract

Accurate and robust classification of medical pathology images is pivotal for computer-aided diagnosis. However, the deployment of deep learning models in high-throughput clinical screening faces a fundamental challenge: the trade-off between diagnostic accuracy and computational efficiency. Current lightweight architectures, while reducing parameter complexity through grouped convolutions, often lead to cross-channel information isolation and diminished representational capacity. In this paper, we propose TetraFuse, a novel framework that systematically integrates features from four complementary domains: space, channel, statistics, and frequency. TetraFuse introduces a novel Cross-Channel Dynamic Aggregation (CCDA) paradigm that reconstructs global channel topology with negligible computational overhead, resolving the inter-group isolation issue. To balance perceptual fidelity and efficiency, we design a stage-aware local enhancement mechanism: Local Variance-Guided Enhancer (LVGE) is employed to filter out shallow-stage background noise, while High-Frequency Boundary Injection (HFBI) reinforces deep-stage pathological contours, preventing spatial over-smoothing. Experimental results on the COVID-19, ISIC 2018, and Kvasir datasets confirm that TetraFuse outperforms state-of-the-art (SOTA) methods. Notably, TetraFuse-Tiny achieves a transformative 91.53% reduction in FLOPs compared to ResNet50; on the Kvasir dataset, it achieved an accuracy of 0.926 and an AUC of 0.994 with only 0.345G FLOPs. By combining high representational power with minimal computational demand, TetraFuse offers a scalable solution for large-scale medical image analysis, especially in resource-constrained clinical environments.

Preprint server: bioRxiv
The authors list and abstract were imported from bioRxiv on 07 Jun 2026.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this preprint? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 24
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement