Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Significance of coherent mapping in unveiling slow conduction zones of ventricular tachycardia substrate in ischemic cardiomyopathy.

Created on 21 May 2025

Authors

Kivanc Yalin, Baris İkitimur, Ali Ugur Soysal, Hakan Yalman, Arda Ceviker, Sukran Nur Sanli, Ahmet Atil Aygun, Gunduz Incesu, Metehan Miroglu, Eymen Yogurtcu, Selin Ismailoglu, Sila Ozturk, Osman Talha Ercan, Hagai Yavin, Timothy Larsen, Paul Rhodes, Ahmet Kaya Bilge, Henry Huang, Tolga Aksu

Published in

Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. May 21, 2025. Epub May 21, 2025.

Abstract

Identifying slow conduction zones (SCZs) within the ventricular tachycardia (VT) substrate remains a major challenge in ischemic cardiomyopathy (ICM). We aimed to evaluate the role of coherent mapping (CM) in identifying SCZs within low-voltage areas (LVAs) in VT substrate mapping and assess its impact on VT ablation outcomes.
This retrospective study included 32 patients with ICM who underwent ablation for recurrent VT. CM-SCZs were compared with traditional substrate markers, including late potentials (LPs), local abnormal ventricular activities (LAVAs), and ILAM-based deceleration zones (DZs). Ablation strategies targeting CM-SCZs were analyzed in relation to procedural and clinical outcomes, including VT recurrence and total radiofrequency (RF) ablation time.
CM-SCZs were consistently identified adjacent to LVAs in all cases, with a mean area of 5.2 ± 2.3 cm2. CM-SCZs colocalized with ILAM-based DZs in 56.3% of cases and overlapped with LPs and LAVAs in selected patients. Among patients who remained free from VT recurrence, total RF ablation time was significantly longer (938 ± 354 vs. 380 ± 448 s, p = 0.03), suggesting that more extensive substrate modification played a role in arrhythmia suppression. Furthermore, patients with VT recurrence had lower post-ablation non-inducibility rates (50% vs. 91.6%, p = 0.02).
CM improves the identification of SCZ within the VT substrate and enhances substrate-based ablation strategies. Incorporating CM-SCZs into VT ablation protocols may improve procedural success and reduce arrhythmia recurrence. Future studies should validate these findings and explore role of CM in broader patient populations.

PMID:
40397327
Bibliographic data and abstract were imported from PubMed on 21 May 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 23
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement