Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Accuracy of intraoral scans of the edentulous maxilla - an in vitro study.

Created on 17 Jun 2025

Authors

Panagiotis Kontis, Jan-Frederik Güth, Christine Keul

Published in

Clinical oral investigations. Volume 29. Issue 7. Pages 342. Jun 17, 2025. Epub Jun 17, 2025.

Abstract

Investigation of the accuracy of various digitalization methods and the accuracy of digitalization of different regions of the edentulous maxilla.
A PEEK edentulous maxilla with four spherical reference geometries served as the testing model. A reference dataset (REF) was generated using a highly accurate 3D measuring instrument. The testing model was digitized as follows (n = 25/group). Direct digitalization (DD) with intraoral scanners (IOS): 1) Cerec AC Primescan (PRI), 2) Trios 4 Move (TR4), 3) Trios 3 Wireless (TR3), 4) Indirect digitalization of PVS impression with laboratory scanner 3Shape D810 (D8I). Three-dimensional deviations between REF and TEST were evaluated (GOM Inspect) in different areas of the model: 1) Complete Surface, 2) Alveolar Ridge, 3) Vestibular Ridge, 4) Palate, 5) Posterior Seal, 6) Border. Significant differences were analyzed with the Games-Howell test for trueness (p < 0.05) and multiple comparisons Levene's test for precision (for IOS: p < 0.008, for area: p < 0.003).
Group D8I revealed the best trueness for Complete Surface (7.95 µm), Palate (9.11 µm), and Border (20.22 µm). Alveolar Ridge showed for PRI (16.45 µm) and TR4 (8.96 µm) the highest trueness. Groups TR4 and PRI resulted in significantly higher precision for Alveolar Ridge. Groups TR4 and D8I demonstrated the highest precision for Palate. Complete Surface and Alveolar Ridge showed for all digitalization methods significantly higher precision.
Indirect digitalization of impressions remains the most accurate approach for capturing edentulous jaws, whereas IOS deliver datasets with clinically acceptable accuracy. Peripheral regions characterized by limited accessibility and smooth surface morphology tend to demonstrate increased deviations in the resulting digital datasets.
Indirect digitalization of the impression still appears to be the most appropriate technique to access the clinical workflow for full dentures due to the superior digitalization trueness and inclusion of functional movements. Direct and indirect digitalization show nearly equal values for precision.

PMID:
40524076
Bibliographic data and abstract were imported from PubMed on 17 Jun 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 35
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement