A predictive model for body water and fluid balance using 3D smartphone anthropometry.

Created on 08 Jul 2025

Authors

Austin J Graybeal, Abby T Compton, Sydney H Swafford, Caleb F Brandner, Molly F Johnson, Maria G Kaylor, Hunter Haynes, Jon Stavres

Published in

Frontiers in physiology. Volume 16. Pages 1577049. Epub Jun 23, 2025.

Abstract

Body fluid volumes, including total body water (TBW), extracellular fluid (ECF), and intracellular fluid (ICF), are crucial indicators of body composition, and the distribution of these fluids is essential for assessing hydration status and fluid accumulation. Although fluid volumes are commonly measured with bioelectrical impedance devices, several challenges hinder the application of this technique. However, 3D smartphone scanning applications that automate body volumes and other anthropometric estimates may provide a viable alternative to body fluid assessments.
A total of 338 participants underwent fluid volume assessments using bioelectrical impedance spectroscopy (BIS) and collected body volumes and anthropometric data using a 3D smartphone scanning application. Then, LASSO regression was used to develop new TBW and ECF prediction model in a subset of participants (n = 272), which was subsequently tested in the remaining participants (n = 66). Smartphone-derived ICF was calculated as the difference between smartphone-predicted TBW and ECF. Fluid overload and imbalance were determined using ECF/TBW and ECF/ICF, respectively, and subsequently predicted from the retained variables using receiver operating characteristic curve analyses and logistic regression.
Estimates from each of the newly-developed prediction models were not significantly different from the estimates produced using BIS (all p ≥ 0.70) and revealed acceptable agreement (TBW: R 2 = 0.91, RMSE = 3.24 L; ECF: R 2 = 0.94, RMSE = 1.10 L; ICF: R 2 = 0.87, RMSE = 2.29 L) when evaluated in the testing sample (n = 66), although proportional bias was observed (p < 0.001). Smartphone-predicted fluid overload (AUC: 0.81 [95%CI: 0.70, 0.92]; sensitivity + specificity: 1.53 [95%CI: 1.39, 1.67]) and imbalance (AUC: 0.76 [95%CI: 0.64, 0.88]; sensitivity + specificity: 1.40 [95%CI: 1.24, 1.56]) demonstrated acceptable diagnostic performance.
Smartphone scanning applications can accurately assess body fluid volumes and imbalances, presenting new possibilities for health screening beyond clinical environments.

PMID:
40626043
Bibliographic data and abstract were imported from PubMed on 08 Jul 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 18
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement