Mid-term outcomes after aortic valve replacement in patients under 70: A comparative study of INSPIRIS RESILIA versus PERIMOUNT MAGNA EASE bioprostheses.

Created on 26 Jul 2025

Authors

Gabriel Saiydoun, Elie Nassar, Saadé Saadé, Chadi Aludaat, Sylvain Rubin, Ibrahim Alqdeimat, Vito Giovanni Ruggieri

Published in

Interdisciplinary cardiovascular and thoracic surgery. Jul 25, 2025. Epub Jul 25, 2025.

Abstract

INSPIRIS RESILIA, launched in 2017, is a bioprosthetic aortic valve developed to improve durability and facilitate future valve-in-valve procedures. Despite its advanced design, many surgeons continue to use the PERIMOUNT MAGNA EASE valve, which has long-standing clinical validation. This study aimed to compare mid-term clinical and echocardiographic outcomes in patients under 70 undergoing aortic valve replacement with either prosthesis.
We conducted a retrospective study of patients who underwent surgical aortic valve replacement between January 2018 and May 2023 at the University Hospital of Reims. The primary outcome was all-cause mortality at one year following surgical aortic valve replacement. Secondary outcomes included haemodynamic parameters, left ventricular ejection fraction, and major postoperative complications such as reintervention, stroke, pacemaker implantation, mediastinitis, transfusion, and new-onset atrial fibrillation.
A total of 300 patients were included: 52 received the INSPIRIS RESILIA valve and 248 received the PERIMOUNT MAGNA EASE valve. After matching, 52 patients from each group were compared. All-cause mortality at three years was 0% in the INSPIRIS group and 1.9% in the PERIMOUNT group. Mean transvalvular gradients were similar at one year (11.3 vs 11.2 mmHg) and three years (12.9 mmHg for both). Two cases of endocarditis-related reoperation occurred in the INSPIRIS group. No structural valve degeneration requiring surgery was observed. Postoperative aortic regurgitation was trivial or absent. Transfusion rates were lower in the INSPIRIS group (46.1% vs 69.2%, p = 0.017).
INSPIRIS RESILIA and MAGNA EASE valves offer similar mid-term safety and performance in patients under 70 years of age.

PMID:
40712048
Bibliographic data and abstract were imported from PubMed on 26 Jul 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 57
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement