Comparison of Vernier Acuity Measured with Three Different Water-induced Blur Simulation Methods.

Created on 31 Jul 2025

Authors

Vivek Suganthan Ramasubramanian, Aiswaryah Radhakrishnan

Published in

Journal of ophthalmic & vision research. Volume 20. Epub Jul 21, 2025.

Abstract

Human vision is subnormal in an aquatic environment, and studies have used different methods to measure visual functions with water-induced blur (WIB). In this study, we compared vernier acuity measured using three different WIB simulation methods.
Sixty young adults (20 in each group) with best-corrected visual acuity of 6/6 participated in the study. Three different methods, one for each study group, were used to simulate WIB in order to measure the vernier acuity. The methods comprised M1: a glass tank filled with water containing a wave motor to produce waves, M2: a sprinkler with uncontrolled water splash against the glass, and M3: a sprinkler with controlled water splash against the glass. For each of the three methods, vernier acuity was measured binocularly (three trials of 50 presentations each) both at baseline (without simulated WIB) in the absence of WIB and under simulated WIB. This was conducted using FrACT presented on the Display++ monitor at a distance of 2 meters from the participant. The vernier target consisted of two vertical lines (1 x 15 arcmin) with a vertical separation of 0.5 arcmin.
The mean baseline vernier acuity (arcsec) was found to be similar (F[2, 57] = 0.20, P = 0.82) among all three groups (M1: 13.28 ± 5.84, M2: 14.44 ± 6.34, M3: 14.05 ± 3.28). Vernier acuity with simulated WIB was least degraded with M1 (19.84 ± 8.40) and more degraded with M2 (288.74 ± 56.61), followed by M3 (49.14 ± 20.13). One-way ANOVA revealed a significant difference among the three methods (F [2, 57] = 354.72, P < 0.001).
Our results suggest that the impact of simulated WIB on vernier acuity is not comparable due to differences in the strength of blur and the varied spatial and temporal properties of different simulated WIB methods. This emphasizes the need to develop a blur metric specific to WIB to objectively quantify its effect on different visual functions.

PMID:
40741421
Bibliographic data and abstract were imported from PubMed on 31 Jul 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 72
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement