Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Training on a 3D-Printed Simulation Model Improves Accuracy in External Ventricular Drain Placement.

Created on 23 Aug 2025

Authors

Michael Kosterhon, Merih Ö Turgut, Matthias Gielisch, Julian Graef, Florian Ringel

Published in

Operative neurosurgery (Hagerstown, Md.). Volume 29. Issue 3. Pages 418-427. Feb 18, 2025. Epub Feb 18, 2025.

Abstract

External ventricular drain (EVD) placement is a critical, lifesaving procedure in cranial neurosurgery, often performed manually using anatomical landmarks that vary between individuals. This study evaluates the efficacy of a 3-dimensional (3D)-printed EVD training model designed to improve the accuracy of this procedure.
Computed tomography scans from 3 patients were used to create 3D-printed head models with narrow, wide, and normal ventricles. Twenty-five neurosurgeons participated in a three-round training protocol: pre-training, training with neuronavigation and a standardized protocol, and post-training. The accuracy of EVD placement was measured using an optical navigation system, and participants' confidence levels were assessed through questionnaires.
Training significantly enhanced EVD placement accuracy. Pre-training, only 55.3% of placements were intraventricular (Kakarla grade 1), which increased to 84.0% post-training (P < .001). The distance to the ideal entry point improved from 5.8 mm (SD, ±3.7 mm) to 4.1 mm (SD, ±1.5 mm), and the distance to the target point improved from 12.6 mm (SD, ±5.8 mm) to 8.3 mm (SD, ±4.0 mm) (P < .001 for both). The time to identify entry points and puncture the ventricles also improved significantly. Left-sided EVDs were more frequently misplaced. In addition, right-handed participants (n = 24) performed better when placing left-sided EVDs with their right hand. Participants with more than 6 years of experience were more likely to misplace the EVD and overestimate their placement accuracy compared with less experienced participants. Post-training, both experienced and less experienced neurosurgeons achieved similar success rates. Confidence in EVD placement and puncture direction significantly increased post-training.
A standardized training protocol using a 3D-printed model significantly improves the accuracy and confidence of neurosurgeons in EVD placement. Regular training is recommended to maintain high clinical performance, emphasizing the need for standardized procedures and the use of neuronavigation for complex cases.

PMID:
40845284
Bibliographic data and abstract were imported from PubMed on 23 Aug 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 56
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement