An innovative sampling device for size-fractionating airborne particulate matter for improved air pollution control of metal(oid)s and polycyclic aromatic hydrocarbons.

Created on 29 Aug 2025

Authors

Anja Ilenič, Radmila Milačič Ščančar, Marija Đurić, Alenka Mauko Pranjić, Janez Ščančar

Published in

Analytical methods : advancing methods and applications. Aug 29, 2025. Epub Aug 29, 2025.

Abstract

A sampling device was developed for collecting and size-fractionating airborne particulate matter (PM). A low-volume cascade system with polytetrafluoroethylene membrane filters (PM10, PM2.5, and PM0.1) connected to an ultrapure-water trap was used to retain the PM<0.1 fraction that passed through the filters. In the collected samples, metal(oid)s and platinum group elements (PGEs) were determined by inductively coupled plasma mass spectrometry after microwave-assisted digestion using a mixture of acids. Polycyclic aromatic hydrocarbons (PAHs) were extracted with a solvent mixture of acetone and petroleum ether, assisted by mechanical shaking and determined by gas chromatography mass spectrometry. The analytical methods were optimised and validated using the urban PM Standard Reference Material 1648a. Measurement repeatability and accuracy were 6% and 2% for metal(oid)s and PGEs, and 3% and 6% for PAHs, respectively. Field emission scanning electron microscopy analysis confirmed that the sampling device efficiently fractionated airborne PM to nano-sized particles. The sampling device was successfully applied to collect PM, enabling effective air pollution monitoring in urban areas. Analysis revealed that metal(oid)s were most abundant in PM10, while those originating from traffic were also elevated in PM<0.1. High-molecular-weight PAHs were distributed between PM10 and PM2.5 fractions. The sampling device provides valuable insights into the chemical composition of (ultra)fine particles, overcoming the limitations of filter-based PM fractionation and providing improved air pollution control for nanoparticle-bound pollutants.

PMID:
40878668
Bibliographic data and abstract were imported from PubMed on 29 Aug 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 21
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement