Performance of hybrid diffuse reflectance spectroscopy (HDRS-ISO 23698) methodology for assessment of sunscreen protection in the ALT-SPF Consortium validation study.

Created on 01 Sep 2025

Authors

Eduardo Ruvolo, Curtis Cole, Mathias Rohr, Jay Silverman, Omid Yousefian, Jan Batzer, Nele Lange, Rita Touti, Florence Pouradier, Luciano Nogueira, Bertrand Colson

Published in

International journal of cosmetic science. Volume 47 Suppl 1. Pages 53-77.

Abstract

Alternative methods to the traditional in vivo sun protection factor (SPF) test are desirable for many reasons. Hybrid DRS (HDRS) (combining in vitro transmission spectroscopy with in vivo DRS spectroscopy) was used in an extensive ring study to characterize its ability to estimate topical sunscreen protection and compared with the currently recognized 'gold standard' human in vivo Sun Protection Factor (SPF-ISO24444), Ultraviolet-A Protection Factor (UVA-PF), and Critical Wavelength (CW) (ISO 24443) Reference Methods sponsored by the Alternative SPF Consortium.
Diffuse reflectance spectroscopy (DRS) of skin provides a rapid, convenient non-invasive tool to evaluate skin properties as well as the optical properties of materials applied to the skin, such as sunscreens. DRS methodology combines in vivo measurement of sunscreen absorbance on skin in the Ultraviolet A (UVA) region with full spectrum in vitro spectrophotometric absorbance scans to provide a full spectrum measurement of the protection of sunscreen on skin.
Results from testing with both monochromatic and polychromatic HDRS devices provided strong correlation of SPF, UVA-PF and Critical Wavelength results with their corresponding 'gold standard' counterpart methods in Study 1 for bias (or 'accuracy'), however with more variability within certain product types. Further training of personnel conducting the HDRS studies was conducted prior to a second follow-up ring study using many of the same blinded samples from Study 1 in addition to Reference Standard sunscreens.
The results showed marked improvement in the variability to a level equivalent to the reference methods while maintaining accuracy of the estimates of the protection values. Virtually all estimates were within the Prediction Intervals (PI) of the reference methods for the second study. HDRS offers the ability to accurately assess sunscreen performance for SPF, UVA-PF as well as CW without invasive damage to test subjects and offers in the future the opportunity to assess water resistance performance.

PMID:
40888058
Bibliographic data and abstract were imported from PubMed on 01 Sep 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 101
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement