Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

AI-Driven Fetal Liver Echotexture Analysis: A New Frontier in Predicting Neonatal Insulin Imbalance.

Created on 08 Sep 2025

Authors

Karine S Da Correggio, Luís Otávio Santos, Felipe S Muylaert Barroso, Roberto N Galluzzo, Thiago Z L Chaves, Aldo von Wangenheim, Alexandre S C Onofre

Published in

Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. Sep 08, 2025. Epub Sep 08, 2025.

Abstract

To evaluate the performance of artificial intelligence (AI)-based models in predicting elevated neonatal insulin levels through fetal hepatic echotexture analysis.
This diagnostic accuracy study analyzed ultrasound images of fetal livers from pregnancies between 37 and 42 weeks, including cases with and without gestational diabetes mellitus (GDM). Images were stored in Digital Imaging and Communications in Medicine (DICOM) format, annotated by experts, and converted to segmented masks after quality checks. A balanced dataset was created by randomly excluding overrepresented categories. Artificial intelligence classification models developed using the FastAI library-ResNet-18, ResNet-34, ResNet-50, EfficientNet-B0, and EfficientNet-B7-were trained to detect elevated C-peptide levels (>75th percentile) in umbilical cord blood at birth, based on fetal hepatic ultrasonographic images.
Out of 2339 ultrasound images, 606 were excluded due to poor quality, resulting in 1733 images analyzed. Elevated C-peptide levels were observed in 34.3% of neonates. Among the 5 CNN models evaluated, EfficientNet-B0 demonstrated the highest overall performance, achieving a sensitivity of 86.5%, specificity of 82.1%, positive predictive value (PPV) of 83.0%, negative predictive value (NPV) of 85.7%, accuracy of 84.3%, and an area under the ROC curve (AUC) of 0.83 in predicting elevated neonatal insulin levels through fetal hepatic echotexture analysis.
AI-based analysis of fetal liver echotexture via ultrasound effectively predicted elevated neonatal C-peptide levels, offering a promising non-invasive method for detecting insulin imbalance in newborns.

PMID:
40920364
Bibliographic data and abstract were imported from PubMed on 08 Sep 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 40
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement