Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Biomechanical Analysis of Prosthetic Designs Retained by Two or Four Implants in the Edentulous Mandible: A Three-Dimensional Finite Element Analysis.

Created on 28 Sep 2025

Authors

M Tuzlali, Ebg Aygun, M Kocacikli, H S Gumus

Published in

Nigerian journal of clinical practice. Volume 28. Issue 9. Pages 1097-1110. Sep 01, 2025. Epub Sep 27, 2025.

Abstract

Edentulism remains a prevalent condition worldwide, significantly compromising masticatory efficiency, quality of life, and oral health. Various implant-retained and implant-supported prosthetic options have been developed to address mandibular edentulism, yet their biomechanical performance under functional loading remains incompletely understood.
To compare stress distribution among seven prosthetic designs for the edentulous mandible: two-implant bar and locator overdentures; four-implant bar and locator overdentures; an anterior fixed-posterior removable prosthesis retained with clasps; its precision-attachment variant; and an All-on-Four fixed prosthesis.
A 3D finite element model of a D2-quality mandible (2-mm cortical, 1-mm mucosa, remaining cancellous bone) was created. Standard implants (4.3×11 mm) and distal-tilted (30°) long implants (4.3×14 mm) were simulated. A 100-N load was applied on the mandibular first molar vertically and obliquely. Literature-based material properties were assigned. Outcomes were implant von Mises stress and cortical bone maximum and minimum principal stresses.
The lowest implant and bone stresses occurred in the anterior fixed-posterior clasp-retained design. Non-rigid connections (bar, locator, clasp) reduced implant stresses compared with precision attachments and fully implant-supported designs. Four-implant overdentures showed higher crestal stress than two-implant counterparts, likely due to greater framework rigidity and distal implant proximity to the load. Precision-attachment hybrid and All-on-Four configurations generated higher stresses at the implant neck and crestal cortical bone. Oblique loading produced higher stresses than vertical across all models.
Within the limits of an idealized, fully osseointegrated FEA, the anterior fixed-posterior clasp-retained prosthesis provided the most favorable stress distribution, supporting consideration of cost-effective, tissue-supported, non-rigid designs for selected mandibular edentulous cases. Increasing implant number did not uniformly reduce stresses; design rigidity and implant position were more influential than implant count. Clinical studies are warranted to validate these simulations.

PMID:
41014536
Bibliographic data and abstract were imported from PubMed on 28 Sep 2025.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 39
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement