Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Biomechanical evaluation of fixation techniques for isolated Letenneur Type I lateral Hoffa fractures: A cadaveric model.

Created on 19 Jun 2026

Authors

Çağatay Baltacı, Peri Kından Baltacı, Hakan Kocaoğlu, Halil İbrahim Açar, Yunus Uslan, Mahmut Kalem

Published in

The Knee. Volume 62. Pages 104548. Jun 18, 2026. Epub Jun 18, 2026.

Abstract

The aim of this study was to biomechanically evaluate and compare five different fixation techniques for isolated Letenneur Type I lateral Hoffa fractures using a fresh-frozen cadaveric model under both static and dynamic axial loading conditions.
Twenty-five fresh-frozen distal femurs were homogeneously assigned to five groups based on fixation method: (A) two postero-anterior (PA) screws (6.5 mm), (B) two antero-posterior (AP) screws (6.5 mm), (C) two PA screws combined with a posterior 3.5-mm tubular plate, (D) one PA screw combined with a lateral 3.5-mm locking compression plate (LCP), and (E) two AP screws combined with a lateral horizontal 3.5-mm tubular plate. Specimens underwent dynamic loading (2500 cycles, five stages, 2 Hz) followed by static axial loading using a servo-hydraulic testing machine. The parameters evaluated included load at 3-mm displacement, ultimate load, stiffness, and photogrammetric displacement.
Plate-augmented constructs demonstrated significantly superior biomechanical stability. Ultimate load was highest in Group C (1761.8 ± 299.5 N), followed by Group D (1564.4 ± 162.1 N) and Group E (1571.2 ± 420.8 N), all significantly greater than Groups A (902.4 ± 522.8 N) and B (1088.2 ± 323.1 N) (P < 0.01). Photogrammetric displacement was significantly lower in plate-augmented groups (Group C: 0.32 ± 0.24 mm; Group E: 0.59 ± 0.58 mm) (P < 0.05). No statistically significant differences were observed between screw-only constructs.
Plate-augmented fixation provides superior biomechanical stability for isolated Letenneur Type I lateral Hoffa fractures. Lateral plating achieves comparable stability to posterior plating while avoiding the technical challenges. The comparable performance of screw configurations suggests that screw trajectory can be flexibly selected based on fracture morphology. These findings offer guidance for surgical planning and implant selection in the management of these complex fractures.

PMID:
42314239
Bibliographic data and abstract were imported from PubMed on 19 Jun 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 1
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement