Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Optimal MRI sequence for predicting extraprostatic extension in prostate cancer: comparison of LCC and MaxRADD measurements.

Created on 24 Jun 2026

Authors

Gorun Ilanjian, Jade Matthey, Fabio Porões, Massimo Valerio, Adrien Richemond, Julien Dagher, Arnas Rakauskas, Clarisse Dromain, Mario Jreige, Naïk Vietti-Violi

Published in

Abdominal radiology (New York). Jun 24, 2026. Epub Jun 24, 2026.

Abstract

Accurate preoperative identification of extraprostatic extension (EPE) in prostate cancer (PCa) is important for treatment strategies. This retrospective study aimed to determine which MRI sequence provides the most accurate measurement of length of capsular contact (LCC) and maximum lesion radial distance (MaxRADD) for predicting EPE.
We included 63 patients who underwent radical prostatectomy for biopsy-confirmed PCa and had preoperative multiparametric MRI (mpMRI) from 2018 to 2020. Two radiologists measured LCC and MaxRADD on T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) maps, and dynamic contrast-enhanced (DCE) sequences. LCC was evaluated using 10 mm and 15 mm thresholds based on Prostate Imaging-Reporting and Data System (PI-RADS) and European Society of Urogenital Radiology (ESUR) guidelines. Histopathology was the reference standard. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated.
63 patients with 105 evaluable lesions were included. Significant differences were observed between the 10 mm and 15 mm LCC thresholds for predicting EPE. At 10 mm, DCE demonstrated the highest sensitivity (90.1%) and a 80.7% specificity. At 15 mm, DCE achieved higher specificity (94.7%) with 85% sensitivity. ROC analysis identified 14 mm on DCE as the optimal LCC threshold, reaching 90% sensitivity, 96.6% specificity (AUC:0.93). MaxRADD showed variable diagnostic performance, with the highest AUC on DCE (0.83), T2WI (0.80), DWI (0.78), and ADC (0.74), without significant differences. Combining LCC and MaxRADD slightly improved AUC (0.96 vs. 0.93 for LCC alone, p = 0.270). MaxRADD performed best on DCE at an 11 mm threshold (sensitivity 65%, specificity 88.5%).
DCE provides the highest diagnostic performance for predicting EPE using LCC measurements, with a 14 mm LCC and 11 mm MaxRADD threshold yielding the best overall accuracy. Combining LCC and MaxRADD numerically increased AUC (0.96 vs. 0.93), however without significant differences in EPE prediction (p = 0.270).

PMID:
42340465
Bibliographic data and abstract were imported from PubMed on 24 Jun 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement