Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Suture residues are associated with histomorphological changes in failed anterior cruciate ligament hamstring autografts.

Created on 25 Jun 2026

Authors

Steffen F Siemoneit, Alexander Bosse, Steffen T Ubl, Daniel Günther, Julius M Wehrmann, Bertil Bouillon, Maiti Münchgesang, Thomas R Pfeiffer

Published in

Journal of experimental orthopaedics. Volume 13. Issue 2. Pages e70811. Epub Jun 23, 2026.

Abstract

This study aimed to evaluate histomorphological changes associated with residual foreign material in failed anterior cruciate ligament (ACL) autografts. We hypothesised that retained suture material is associated with histopathological regression phenomena in ligamentous and osseous compartments following ACL reconstruction failure.
In this prospective study, 43 consecutive patients (mean age 29.7 ± 9.0 years; 20.9% female) undergoing revision surgery after failed autologous ACL reconstruction were included and analysed. A total of 76 bone-graft specimens were obtained by over-reaming femoral and tibial drill tunnels to retrieve the periarticular tunnel segment. Specimens were processed using Hematoxylin-Eosin, Masson-Goldner and Elastika-van Gieson staining. Morphological alterations related to foreign material were assessed qualitatively and semi-quantitatively using a four-point grading system under light microscopy. Evaluations were performed independently by two observers (a pathology professor and a trained investigator), with consensus in case of disagreement.
Foreign material residues were identified in 92.6% of specimens. Polarised light microscopy revealed birefringent suture remnants frequently associated with histiocytic inflammatory reactions and multinucleated giant cells. Observed regression phenomena included inflammatory reactions (IR), capillary proliferation (CP), osteonecrosis (ON), fissural splitting (FS) and intraligamentous cyst formation. Severe tissue destruction of the autograft or bony compartment was present in approximately 20% of femoral and tibial samples. Descriptive contingency analysis indicated that regression phenomena predominantly occurred in association with adjacent foreign body reactions, whereas isolated regression changes without detectable foreign material were rare.
Residual suture material in failed ACL reconstructions is frequently associated with inflammatory and degenerative histomorphological changes in both tendon graft and bone tunnel compartments. Although causality cannot be established, these findings suggest that foreign body reactions may contribute to local tissue degradation. Further studies are needed to clarify the clinical and biomechanical relevance of these observations.
N/A.

PMID:
42344959
Bibliographic data and abstract were imported from PubMed on 25 Jun 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement