A label-free nanoplasmonic biosensor for intraoperative discrimination of tumor margins in brain metastases surgery.

Created on 29 Jun 2026

Authors

Víctor García-Milán, Laura Bauluz Olmedo, Sara Marcos, Ruth Lau, Rubén Martín-Láez, Javier Chicote, María Luisa Díaz Fernández, Dennis Céspedes, Dolores Ortiz, Fernando Moreno, José L Fernández-Luna, Alfredo Franco, Carlos Velásquez

Published in

Journal of neuro-oncology. Volume 178. Issue 3. Jun 27, 2026. Epub Jun 27, 2026.

Abstract

Brain metastases have traditionally been considered well-demarcated lesions; however, increasing evidence demonstrates frequent microscopic infiltration of the surrounding brain parenchyma, with relevant prognostic implications, despite current intraoperative tools. The aim of this study was to evaluate the feasibility and diagnostic performance of a label-free nanoplasmonic biosensor for intraoperative discrimination between tumor tissue and peritumoral brain in brain metastases surgery.
A prospective multicenter study was conducted in patients undergoing surgical resection of brain metastases. Paired tumor and adjacent peritumoral tissue samples were collected intraoperatively following a standardized protocol across participating centers. Samples were analyzed ex vivo using a plasmonic nanostructured biosensor, which detects tissue-specific refractive index differences. Histopathological examination served as the reference standard. Paired comparisons were performed using the Wilcoxon signed-rank test, and diagnostic performance was assessed using receiver operating characteristic analysis.
Twenty paired tumor and peritumoral samples from a consecutive series of 20 patients were analyzed. Refractive index values were significantly higher in tumor tissue compared with peritumoral brain (p = 0.0008). In 85% of cases, tumor samples showed higher refractive index values than their paired peritumoral counterparts. Using the optimal cut-off value, sensitivity was 76% and specificity was 68%.
Tumor and peritumoral brain tissue can be discriminated through the measurement of intrinsic biophysical properties with a label-free nanoplasmonic biosensor, supporting its potential role as an objective intraoperative tool for margin assessment without the need of exogenous agents.

PMID:
42371195
Bibliographic data and abstract were imported from PubMed on 29 Jun 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement