Redefining robotic image-guidance - tomographic visualization of lesions during prostate cancer surgery via gantry-free robotic SPECT.

Created on 01 Jul 2026

Authors

A C Berrens, K Pirkovets, S Azargoshasb, L J Slof, B A Cakal, P J van Leeuwen, E M K Wit, M Sinaasappel, T Wendler, H G van der Poel, M N van Oosterom, F W B van Leeuwen

Published in

European journal of nuclear medicine and molecular imaging. Jul 01, 2026. Epub Jul 01, 2026.

Abstract

The introduction of the drop-in gamma probe has advanced intraoperative molecular imaging during prostate cancer surgery. We have been able to convert the sensor's numeric readout to tomographic images, so-called robotic-SPECT (RoboSPECT) and investigate how this is impacted by radiopharmaceutical avidities and drop-in scan metrics.
The gamma sensor readout was registered with its 3D position and orientation, allowing a custom reconstruction algorithm to generate RoboSPECT images. Evaluations occurred in 21 patients; 10 sentinel node procedures (SN; primary prostate cancer) and 11 PSMA-radioguided surgery (recurrent prostate cancer). RoboSPECT findings were related to respective pre- and intra-operative controls, including preoperative PSMA-PET/CT and/or SPECT/CT images and fluorescence detection (SN only).
RoboSPECT proved to be safe and applicable in a range of conditions. In the SN-group, 26 SN-SPECT/CT lesions were successfully identified with SN-RoboSPECT (100%); 3 were tumor positive (sensitivity 100%). Only 73% of SNs were surgically visible with fluorescence imaging. For the PSMA guided group, the 14 lesions identified on PSMA-PET/CT were all visualized with PSMA-RoboSPECT (100%); 18 specimens were tumor positive (sensitivity 78% for both PSMA-PET/CT and PSMA-RoboSPECT). Preoperative PSMA-SPECT/CT only identified 4 PSMA-lesions (29%). No false positives were seen for roboSPECT and all final resection margins were clean. At 6-months 0% of the SN-patients and 20% of PSMA-patients showed biochemical recurrence.
RoboSPECT provides 3D context that extends the utility of drop-in gamma tracing and assists the alignment between pre- and intra-operative target perception. Here SN-RoboSPECT clearly outperformed fluorescence SN imaging and PSMA-RoboSPECT outperformed preoperative PSMA-SPECT/CT imaging.

PMID:
42384203
Bibliographic data and abstract were imported from PubMed on 01 Jul 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement