Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

STHLM3 NorDCaP: prospective multicentre trial of Stockholm3 for active surveillance biopsy guidance.

Created on 01 Jul 2026

Authors

Nicola Giudici, Simone Scuderi, Thorgerdur Palsdottir, Tobias Nordstrom, Martin Eklund, Eva Ferlev Jensby, Michael Borre, Bodil Ginnerup Pedersen, Henrik Grönberg, Karina Dalsgaard Sørensen, Svein R Kjosavik, Anna Lantz

Published in

BJU international. Jul 01, 2026. Epub Jul 01, 2026.

Abstract

Active surveillance (AS) is the preferred approach for low-risk prostate cancer (PCa). Recent efforts have explored new biomarkers to reduce the frequency of surveillance biopsy. This study assessed Stockholm3 for predicting PCa upgrading during surveillance biopsies.
The prospective STHLM3-AS NorDCaP trial included 199 men with International Society of Urological Pathologists grade group 1 (ISUP GG 1) PCa under AS in Sweden, Denmark, and Norway (2019-2022). All men had ISUP GG 1 PCa and received a Stockholm3 test before surveillance biopsies. The primary outcome was ISUP upgrading, defined as ISUP GG 2 or higher.
At surveillance biopsy, 72 of the 199 (36%) men were upgraded. Men with upgraded PCa had higher median Stockholm3 (35; interquartile range [IQR] 26-50) than those without upgrading (23; IQR 14-34, P < 0.01). The area under the receiver operating characteristic curve (AUC) for Stockholm3 was 0.71 (95% confidence interval [CI] 0.64-0.79). For Stockholm3 ≥15, sensitivity, specificity, and negative-predictive value (NPV) were 0.93 (95% CI 0.85-0.98), 0.26 (95% CI 0.19-0.35), and 0.87 (95% CI 0.72-0.96), respectively, sparing 19% of biopsies while missing five cases (7% of upgrades), none of which were ISUP GG ≥3. At a lower threshold (≥11), sensitivity increased to 0.99 (95% CI 0.93-1.00) with lower specificity (0.11; 95% CI 0.06-0.18) and an NPV of 0.93 (95% CI 0.68-1.00). Prostate-specific antigen density ≥0.15 showed a sensitivity of 0.60 (95% CI 0.48-0.72), specificity of 0.72 (95% CI 0.63-0.80), and NPV of 0.75 (95% CI 0.66-0.83), with an AUC of 0.71 (95% CI 0.63-0.79). Prostate Imaging-Reporting and Data System score ≥3 demonstrated a sensitivity of 0.92 (95% CI 0.83-0.97), specificity of 0.33 (95% CI 0.22-0.44), and NPV of 0.84 (95% CI 0.66-0.95), with an AUC of 0.72 (95% CI 0.65-0.79).
In men with low-risk PCa under AS, Stockholm3 may enhance risk stratification and reduce unnecessary biopsies. Prostate-specific antigen density and multiparametric magnetic resonance imaging showed comparable performance, with Stockholm3 providing a potentially practical blood-based complement in a multimodal strategy.

PMID:
42383465
Bibliographic data and abstract were imported from PubMed on 01 Jul 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 1
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement