Method for correcting the temperature dependence of field-type glass electrode pH sensors.

Created on 21 Jul 2026

Authors

Kei Okamura, Takuroh Noguchi, Mayumi Hatta

Published in

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry. Jul 21, 2026. Epub Jul 21, 2026.

Abstract

Seawater pH measurement is essential for monitoring ocean acidification and its biogeochemical impacts. Glass electrode pH sensors are widely used for in situ applications due to their ease of operation, low power consumption, and no reagent requirements. However, their accuracy can be affected by temperature-dependent effects, particularly those associated with the internal reference solution. Conventional calibration methods based on the Nernst response do not explicitly account for temperature-induced variations in the internal solution, which may lead to systematic bias under conditions with large temperature gradients. In this study, a correction method is proposed to address temperature-dependent errors by modeling the internal pH (pHin). The model incorporates two primary temperature-dependent contributions: the intrinsic temperature dependence of the phosphate buffer and potential shifts caused by activity changes in saturated KCl. These effects are combined through the electrode response factor (fR), defined as the ratio of the observed electrode slope to the theoretical Nernst slope, to estimate pHin as a function of temperature and correct measured pH values to a reference temperature of 25 °C. Application of the method to vertical seawater profiles demonstrated a reduction in deviation from colorimetric reference measurements. The corrected results showed reduced temperature-dependent bias across depth. This approach provides a practical framework for improving the reliability of in situ glass electrode pH measurements under varying thermal conditions. The proposed method addresses equilibrium temperature-dependent effects of the internal solution but does not explicitly account for transient hysteresis, pressure effects, or long-term sensor drift.

PMID:
42479380
Bibliographic data and abstract were imported from PubMed on 21 Jul 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement