Haptic Portable Robotic Device for Automated Guidewire or Catheter Navigation in Endovascular Procedures.

Created on 29 Jul 2026

Authors

Vahid Mohammadi, Jason MacTaggart, Majid Jadidi, Alexey Kamenskiy

Published in

Annals of biomedical engineering. Jul 28, 2026. Epub Jul 28, 2026.

Abstract

Endovascular therapy is preferred over open surgery due to its minimally invasive nature, faster recovery, and lower perioperative risk; however, fluoroscopy guided procedures are limited by radiation exposure, high equipment costs, and reliance on highly skilled operators. This study aims to develop and evaluate a lightweight, portable robotic system for autonomous guidewire navigation to improve safety, accessibility, and operator independence.
A compact 400 g robotic device was designed with millimeter scale positioning accuracy, servo current-based real-time haptic feedback, precise axial rotation, automated retraction advance control, and compatibility with standard endovascular tools. Miniature linear actuated servomotors replicate skilled manual maneuvers using impedance control. Upon tip contact, the system advances the guidewire by 1 mm, measures current changes, classifies lesion stiffness (soft, medium, stiff), and adapts virtual mass-spring-damper gains to regulate push speed and applied force. Bench experiments were conducted using flexible tubing with inserts simulating 20-80% stenosis and two current thresholds (75 and 94 mA).
Retraction frequency increased with stenosis severity, validating the autonomous control strategy. Lesion stiffness classification achieved F-scores of 0.83, 0.77, and 0.95 for soft, medium, and stiff conditions, respectively, demonstrating reliable discrimination and adaptive force modulation.
The proposed system enables autonomous and adaptive guidewire advancement with high classification accuracy using low-cost, current-based sensing and impedance control. Its lightweight and portable design reduces dependence on continuous manual operation and specialized imaging infrastructure, supporting safer and faster interventions and potential deployment in prehospital or resource-limited settings. This prototype advances the development of more accessible and operator-independent endovascular therapy.

PMID:
42521967
Bibliographic data and abstract were imported from PubMed on 29 Jul 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement