Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Generation of chest CT pulmonary nodule images by latent diffusion models using the LIDC-IDRI dataset.

Created on 31 Jul 2026

Authors

Kaito Urata, Maiko Nagao, Atsushi Teramoto, Kazuyoshi Imaizumi, Masashi Kondo, Hiroshi Fujita

Published in

International journal of computer assisted radiology and surgery. Jul 31, 2026. Epub Jul 31, 2026.

Abstract

Lung cancer is the leading cause of cancer-related deaths. Recently, computer-aided diagnosis (CAD) systems have been developed to support diagnosis, but their performance depends heavily on the quality and quantity of training data. However, in clinical practice, it is difficult to collect a large amount of CT images for specific cases, such as small-cell carcinoma with low epidemiological incidence or benign tumors that are difficult to distinguish from malignant ones. This leads to the challenge of data imbalance. In this study, we propose a method to automatically generate chest CT nodule images that capture target features using latent diffusion models (LDM), and verify its effectiveness.
Using the LIDC-IDRI dataset, we created pairs of nodule images and findings based on physician evaluations. For the image-generation models, we used Stable Diffusion version 1.5 (SDv1) and 2.0 (SDv2), which are types of LDM. Each model was fine-tuned using the created dataset. During the generation process, we adjusted the guidance scale (GS) to indicate the fidelity of the input text. Quantitative evaluation used metrics to measure image quality, diversity, and consistency with the text. Subjective evaluation consisted of visual assessments conducted by three radiological technologists.
Quantitative and subjective evaluations showed that SDv2 (GS = 5) achieved the best performance in terms of image quality, diversity, and text consistency. In the subjective evaluation, no statistically significant differences were observed between the generated and real images, no statistically significant differences were detected between SDv2-generated and real ROI images across the evaluated categories.
We propose a method for generating chest CT nodule images based on input text using LDM. The evaluation results demonstrate that the proposed method can generate high-quality images that can successfully capture specific medical features.

PMID:
42536286
Bibliographic data and abstract were imported from PubMed on 31 Jul 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement