Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

[Development of a quality control method for Polygalae Radix and exploration of its inter-column transfer strategy].

Created on 03 Aug 2026

Authors

Hu-Min Xie, Xiao-Qing Cui, Wan-Jin Chen, Chen-Na Lu, Wei-Hong Feng, Xiao-Qian Liu, Xiao-Li Sun, Peng-Yue Li, Yan-Rong Li, Zhi-Min Wang, Chun Li

Published in

Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica. Volume 51. Issue 14. Pages 4040-4052.

Abstract

This study aimed to develop an ultra-performance liquid chromatography(UPLC) method for the quantitative analysis of xanthones and oligosaccharide esters in Polygalae Radix(PR), and to explore a retention-time-ratio-based strategy for inter-column method transfer. Chromatographic separation was performed on a Waters ACQUITY UPLC BEH C_(18) column(2.1 mm×50 mm, 1.7 μm) by gradient elution using 0.1% formic acid in water and acetonitrile with detection at 238 nm. The UPLC fingerprints of 31 batches of PR samples were established, with 21 common peaks marked and identified by UPLC-Q-TOF-MS~E. Through systematic methodological validation, a quantitative method was developed for the simultaneous determination of 7 bioactive components, namely sibiricose A_1, sibiricaxanthone B, polygalaxanthone Ⅷ, polygalaxanthone Ⅺ, polygalaxanthone Ⅲ, 3,6'-disinapoyl sucrose, and tenuifoliside A. A quantitative analysis of multiple components by single marker(QAMS) method was established using polygalaxanthone Ⅲ as the internal reference substance, and its accuracy was compared with that of the external standard method(ESM). The feasibility of method transfer across different columns and instruments was also investigated. All 7 analytes showed good linearity(r>0.999) within their respective concentration ranges with mean recoveries of 94.31%-99.02%(RSD<2.0%, n=6). The relative error(RE) between QAMS and ESM was less than 4.0%, and the paired t-test indicated no significant difference between the two methods. Preliminary studies of method transfer on 9 C_(18) columns from 3 manufacturers on Waters UPLC systems of two models demonstrated that gradient time adjustment based on retention time ratio could maintain the elution behavior and separation characteristics of the target peaks, though the generalizability of this strategy requires further validation. The established UPLC-QAMS method is accurate and reliable for the quality control of PR. The inter-column method transfer strategy provides preliminary reference for the broader application of analytical methods.

PMID:
42543336
Bibliographic data and abstract were imported from PubMed on 03 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement