Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Adjacent segment disease following long segment instrumentation of lumbar spine: A finite element analysis study.

Created on 06 Aug 2026

Authors

P Venkata Sudhakar, Aman Verma, Shivendra Kumar Sinha, Pankaj Kandwal, Bhaskar Sarkar, Inder Vir Singh

Published in

The Indian journal of medical research. Volume 164. Issue 2. Pages 186-193.

Abstract

Background and objectives Adjacent segment degeneration is a recognised consequence of spinal fusion, yet most finite element (FE) analyses emphasise controlled loading conditions such as flexion, extension, rotation, and lateral bending. Limited data exist on how real-world daily activities influence biomechanics at adjacent levels. This study aimed to quantify changes in range of motion and facet joint stresses at uninstrumented segments during common activities of daily living (ADLs) and to evaluate how increasing fusion length alters these parameters. Methods A validated FE model of the lumbosacral spine was developed using CT-based DICOM data from an individual with normal anatomy. After baseline validation against published range of motion data, the model was instrumented for various fusion lengths and subjected to forces representing typical ADLs, including sitting, forward bending with and without load, jumping, and lateral bending. Range of motion and facet joint stresses were recorded at adjacent unfused segments. Results Baseline range of motion values for flexion, extension, rotation, and lateral bending matched literature norms. Instrumentation led to a marked increase in range of motion at adjacent levels across all ADLs. The magnitude of increase rose exponentially with each additional cephalad level incorporated into the fusion construct. Facet joint stresses demonstrated a similar trend and were proportional to activity-related changes in range of motion. Caudal adjacent levels consistently experienced greater stresses than cranial levels. Interpretation and conclusions Adjacent-level range of motion and facet loading rise exponentially with longer fusion constructs, particularly under daily cyclical loads. Caudal segments endure disproportionately higher mechanical demands, potentially predisposing them to earlier degeneration.

PMID:
42555683
Bibliographic data and abstract were imported from PubMed on 06 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 1
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement