Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Ankyras simulation for flow diversion of intracranial aneurysms: a standardized workflow integrated clinical validation study.

Created on 07 Aug 2026

Authors

Alan R Rheaume, Christine Denice, Seyed Morsal Mosallami Aghili, Michael Jean, Carla Guerrero, Lukasz Chojnowski, Daniel Kim, Tasnim Tanim, Eric Birmingham, Ryan J Fernandez, Tiffany Ang, Sanjana Iyer, Shoaib Syed, David Fiorella, Chander Sadasivan

Published in

Journal of neurointerventional surgery. Aug 06, 2026. Epub Aug 06, 2026.

Abstract

Accurate flow diverter (FD) sizing is critical for successful intracranial aneurysm (IA) treatment. We evaluated the predictive performance of the Ankyras FD simulation platform within a standardized simulation based clinical workflow using three-dimensional (3D) DynaCTA centerline analysis as an advanced validation reference standard.
A retrospective analysis of a prospectively maintained institutional database of Ankyras guided IA treatments between April 2024 and October 2025 was performed. 3D rotational angiography data generated Ankyras simulations for treatment planning, device selection, and intraoperative guidance. Simulated length (SL) and proximal landing zone (PLZ) were compared with post-deployment length (DL) from DynaCTA centerline measurements (3D Slicer). Accuracy was assessed using correlation coefficients, mean absolute error (MAE), and Bland-Altman analysis.
54 consecutive patients (48 women, mean age 54.2 years) with 63 IAs underwent 57 pipeline embolization device (PED) treatments. All achieved procedural success without intraoperative complications; two required adjunctive stent placement for malapposition. Mean SL was 21.44±3.53 mm and DL was 21.49±3.52 mm (n=46), with a strong SL-DL correlation (r=0.91), minimal bias (-0.05 mm), and 1.24 mm MAE. PLZ demonstrated a strong correlation (r=0.94), low bias (0.14 mm), and minimal MAE (1.34 mm) between Ankyras and the deployed values (n=45). Bland-Altman analysis showed narrow agreement limits without evidence of proportional error.
Using a robust 3D DynaCTA centerline based validation, Ankyras demonstrated high accuracy for PED deployment length and landing zone prediction within a standardized clinical treatment workflow of pre-procedural planning, intraoperative guidance, and post-deployment assessment.

PMID:
42562635
Bibliographic data and abstract were imported from PubMed on 07 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 13
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement