Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Comparison of Iodinated Contrast Doses Based on Total Body Weight and Lean Body Weight in Pediatric Patients: Impact on Image Quality and Contrast Exposure.

Created on 08 Aug 2026

Authors

L A O da Silva, F D C B Braga, M R R Cardoso, P H F Jordão, L M de Arruda, M O S de C Meneses, A S Souza, R Fernandes-Ferreira

Published in

Radiography (London, England : 1995). Volume 32. Issue 6. Pages 103532. Aug 07, 2026. Epub Aug 07, 2026.

Abstract

Iodinated contrast dosing in pediatric computed tomography (CT) traditionally relies on total body weight (TBW), which may result in excessive contrast administration, particularly in patients with higher adiposity. Lean body weight (LBW)-based protocols have shown promise in adults but remain underexplored in children. Therefore, the aim of this study was to compare contrast volume requirements and hepatic enhancement quality among three dosing protocols: LBW-based, TBW-based, and the Control Group (CG), based on the institutional standard for pediatric abdominal CT.
This prospective study enrolled 66 patients (age 0-16 years) undergoing contrast-enhanced abdominal CT between September 2023 and August 2024. Patients were randomly assigned to receive iodinated contrast (iobitridol 350mg I/mL) dosed by: (1) LBW (0.63 g iodine/kg x LBW, calculated using Peters formula; n = 23), (2) TBW (0.46 g iodine/kg x TBW; n = 20), or (3) institutional control protocol (2 mL/kg x TBW, equivalent to 0.7 g iodine/kg; n = 23). Kruskal-Wallis, ANOVA, Two-way ANOVA, ANCOVA, Scheirer-Ray-Hare, and Cohen's Kappa tests with Likert scale were used.
The LBW group received lower median contrast volumes (27 mL; IQR, 10-80 mL) compared to the TBW group (34.5 mL; IQR, 18-78 mL) and the CG group (40 mL; IQR, 13-80 mL), although the differences did not reach statistical significance (P > 0.05). Notably, this reduction did not compromise hepatic enhancement, which remained comparable to the CG (552 ± 139 HU; P = 0.107).
Lean body weight may be a useful parameter for estimating contrast dose in pediatric abdominal CT, potentially reducing administered volumes without compromising diagnostic image quality.
These results provide early evidence that LBW-based dosing may support more individualized contrast administration in pediatric CT, potentially reducing exposure-related risks.

PMID:
42566807
Bibliographic data and abstract were imported from PubMed on 08 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement