Authors
Shengjie Wu, Kelly Q Jia, Xiangxiang Shi, XingXing Chen, Lan Su
Published in
Cardiac electrophysiology clinics. Volume 18. Issue 3. Pages 269-272. Epub Jul 09, 2026.
Abstract
This case presents a 67-year-old man with familial hypertrophic cardiomyopathy, severe heart failure (LVEF 31%, NYHA III), and significant interatrial conduction delay. After ruling out cardiac resynchronization therapy due to unsuitable ventricular activation characteristics, a dual-chamber implantable cardioverter-defibrillator was implanted, using Bachmann bundle pacing for the atrial lead to optimize interatrial synchrony. BBP successfully corrected the IACD, evidenced by P-wave shortening and normalization. This led to remarkable clinical improvements within 1 month: LVEF increased from 31% to 49%, and NYHA class improved from III to II. Echocardiography confirmed enhanced left atrial-left ventricular coupling. This case demonstrates BBP combined with ICD as a novel and effective strategy for HCM patients with IACD, offering both sudden cardiac death protection and substantial hemodynamic and functional benefits by optimizing atrial activation and atrioventricular synchrony.
PMID:
42580791
Bibliographic data and abstract were imported from PubMed on 12 Aug 2026.
Read full publication at:
Please sign in
to see all details.
Advertisement
Stats
- Recommendations n/a n/a positive of 0 vote(s)
- Views 10
- Comments 0