Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

BioShield-12: A 3D-Printed Conformal Chest Shield for Wireless 12-Lead ECG Acquisition.

Created on 13 Aug 2026

Authors

Ahsan Naveed, Rida-E-Fatima, Zia Mohy Ud Din, Abdullah Al Aishan, Hedi Ammar Guesmi, Jahan Zeb Gul

Published in

Sensors (Basel, Switzerland). Volume 26. Issue 15. Aug 04, 2026. Epub Aug 04, 2026.

Abstract

Reproducible electrode placement remains a critical, unresolved challenge in wearable ECG systems, where manual electrode attachment introduces inter-session positional error that degrades signal morphology and compromises multi-lead representation. Although the 12-lead clinical ECG system is the gold standard, conventional setups are often bulky, wired, and dependent on operator expertise, limiting their use in prehospital or remote care. Recent advancements in wearable and wireless ECG systems have improved mobility and real-time monitoring, but they typically suffer from limited lead coverage, discomfort, and unstable connectivity. This paper introduces BioShield-12, an anatomically adaptive thermoplastic polyurethane (TPU) shield fabricated using fused deposition modeling (FDM) to improve multi-site electrode placement and 12-lead electrocardiogram (ECG) reconstruction from a single-shield design based on anthropometric data from ten healthy adults (five male, five female; sizing cohort). Mechanical characterization confirmed TPU's suitability as a compliant wearable substrate, with toughness of 34.4 MJ/m3 and elastic modulus of 79.1 MPa. Feasibility validation against a research-grade reference (BIOPAC MP36) in twenty healthy subjects (n = 20; 10 male, 10 female; mean age 21 ± 4 years) demonstrated consistent signal fidelity (SNR: 17.5-22.5 dB; Pearson r: 0.93-0.98; power-line interference ratio (PLIR): 1.0-3.2 × 10-5) and confirmed feasibility of 12-lead reconstruction. This work provides proof-of-concept for an additive manufacturing-based conformal electrode interface that eliminates variability in placement without needing individual attachment.

PMID:
42590715
Bibliographic data and abstract were imported from PubMed on 13 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement