Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Impact of sample mass on the reliability of toenail fluoride for exposure assessment.

Created on 15 Aug 2026

Authors

Guillermo Tamayo-Cabeza, Michael Zenni, Gina A Castiblanco-Rubio, Frank Lippert, David B Flora, Janet L Peacock, Christine Till, Carly V Goodman, Bruce P Lanphear, Susan A Korrick, Margaret R Karagas, E Angeles Martinez-Mier

Published in

Toxicology and environmental health sciences. Volume 18. Issue 3. Pages 431-438. Epub Apr 27, 2026.

Abstract

This study aimed to determine the minimum toenail mass needed for reliable fluoride analysis, and to compare fluoride extraction efficiency (%FE) using two protocols.
Toenail samples (n = 98 from 11 participants) were grouped into masses ranging from 1.0 to 5.0 mg (± 0.5 mg). Fluoride content was analyzed using a hexamethyldisiloxane(HMDS)-facilitated diffusion method and a fluoride-ion selective electrode. Pooled toenail samples (3.0 ± 0.5 mg) from four participants were analyzed using two protocols: protocol-A used 1 mL of HMDS-saturated 3N sulfuric acid/2 mL DI water; and protocol-B used 3 mL/3 mL. Samples were re-analyzed twice to calculate %FE. Minimum mass-threshold was determined by intraclass correlation coefficients (ICC) with 95%-confidence intervals (CI) from linear mixed-effects models and change-point analysis, accounting for intra-participant variability. F-tests compared the variance in %FE between protocols.
Fluoride content ranged from 0.82 to 9.22 µg/g. Excellent reliability (ICC = 0.90, 95%CI:[0.71, 0.95]) was observed in samples ≥ 2.5 mg. A change-point was identified at 2.20 mg(95%CI:[1.70, 2.70 mg]). A less variable %FE was observed with protocol-A (43-58%) compared to protocol-B (38-80%) (F-ratio = 0.23, p = 0.02).
Toenail sample mass affects the reliability of fluoride analysis. The use of a minimum toenail mass of about 2.2-2.5 mg increases the reliability of fluoride analysis at the participant level. Variability in %FE should be considered in future efforts to standardize analytical protocols.
The online version contains supplementary material available at 10.1007/s13530-026-00321-y.

PMID:
42601994
Bibliographic data and abstract were imported from PubMed on 15 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 9
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement