Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Long-term outcomes of surgical aortic valve replacement using a third-generation stented bovine pericardial bioprosthesis in 1907 patients.

Created on 16 Aug 2026

Authors

Preetha Pamidighantam, Stephen Thorp, Jason M Aubrey, Caleb Weissman, Lucas Leffler, Taylor Zimmer, Justin Fanning, Stephane Leung Wai Sang, David Ranney, Edward Murphy, Charles Willekes, Tomasz A Timek

Published in

JTCVS open. Volume 32. Pages 101876. Epub May 29, 2026.

Abstract

This large, single-center evaluation presents long-term survival, reintervention, and echocardiographic outcomes after implantation of a third-generation supra-annular stented bovine pericardial aortic valve with a proprietary anticalcification treatment.
After excluding patients with ventricular assist devices, congenital repairs, and heart transplants, 1907 patients underwent aortic valve replacement with this bioprosthetic valve between August 2010 and September 2023. Primary outcomes were freedom from all-cause mortality and reintervention for structural valve deterioration. Secondary outcomes included mean transprosthetic gradient and Valve Academic Research Consortium 3-defined severe hemodynamic valve dysfunction.
Among 1907 patients included, 30-day mortality was 2.8% (N = 54), stroke occurred in 2.8% (N = 53), and a permanent pacemaker was implanted in 3.3% (N = 62). Echocardiographic follow-up was available in 90.46% of patients (mean follow-up: 4 years; total 6557 echocardiograms reviewed). Overall mean transprosthetic gradient was 11.76 ± 6.52 mm Hg, 12.87 ± 7.52 mm Hg, 16.10 ± 11.02 mm Hg, and 16.01 ± 8.31 mm Hg at 1, 5, 10, and 12 years, respectively. Overall survival was 93.25%, 77.62%, 47.99% and 37.84% at 1, 5, 10, and 12 years, respectively. Freedom from stage 3 hemodynamic valve dysfunction was 99.08%, 85.75%, and 64.32% at 5, 10, and 12 years, respectively. Structural valve deterioration-related reintervention occurred in 2.7% of patients (N = 51), with freedom from reintervention at 98.32%, 90.80%, and 85.13% at 5, 10, and 12 years, respectively.
Long-term outcomes of this bioprosthetic valve are characterized by excellent overall survival, low structural valve deterioration rates, and sustained hemodynamic performance through 12 years of follow-up.

PMID:
42604311
Bibliographic data and abstract were imported from PubMed on 16 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 4
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement