A coarse-to-fine framework combining deep learning and Monte Carlo for BNCT patient position optimization toward inverse planning.

Created on 21 Aug 2026

Authors

Yoonho Na, Chang-Min Lee, Kyuri Kim, Hyungjoo Cho, Jimin Lee, Sung-Joon Ye

Published in

Medical physics. Volume 53. Issue 9. Pages e70642.

Abstract

Boron Neutron Capture Therapy (BNCT) utilizes high linear energy transfer (LET) charged particles from the 10B(n,α)7Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planning. Current treatment planning, however, depends on manual forward planning using computationally intensive Monte Carlo (MC) simulations.
We propose an automated patient position optimization framework for BNCT to address these limitations. This method overcomes the computational bottleneck of MC simulations by integrating a rapid deep learning (DL) dose prediction model with a high-fidelity GPU-accelerated MC engine, enabling efficient inverse planning.
We developed a hybrid coarse-to-fine optimization workflow driven by the Trust Region Bayesian Optimization (TuRBO) algorithm. In the coarse stage, a 3D U-Net architecture rapidly identifies promising patient positions. In the fine stage, the solution is refined within a restricted parameter bound using the GPU-accelerated MC engine. We evaluated the framework on the GLIS-RT open dataset (229 glioblastoma patients, split into train, validation, and test sets at a 70:20:10 ratio).
Optimizing the patient position with TuRBO improved target dose and homogeneity over a non-optimized baseline, reaching equivalent plan quality about 5.65× faster than an exhaustive grid search. In the coarse stage, the DL dose predictor ran about 37× faster than the high-fidelity MC. The coarse-to-fine workflow then matched high-fidelity MC plan quality while cutting optimization time by a factor of 2.7, outperforming optimization driven by the DL predictor alone. Two-port plans required no change to the method, where the added geometric freedom raised the mean target dose from 59.96% to 74.91% and lowered the homogeneity index (HI) from 1.226 to 0.647.
We successfully developed a Bayesian optimization (BO) framework for BNCT patient positioning. The proposed coarse-to-fine approach effectively balances computational speed with accuracy, offering a practical way toward automated inverse planning in BNCT.

PMID:
42623144
Bibliographic data and abstract were imported from PubMed on 21 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 13
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement