Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis.

Created on 21 Aug 2026

Authors

Ercin Samunahmetoglu, Ilgın Ari, Arzum Yilmaz

Published in

Journal of prosthodontics : official journal of the American College of Prosthodontists. Aug 21, 2026. Epub Aug 21, 2026.

Abstract

This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant-supported prosthetic systems under varying bone conditions using finite element analysis.
Four three-dimensional (3D) finite element models were developed based on two different anatomical conditions representing Zygoma Anatomy Guided Approach (ZAGA) Type 1 and Type 3. In each ZAGA type, two implant configurations were created by positioning zygomatic implants in different regions: lateral incisor-first molar and first premolar-first molar. All models were subjected to vertical and oblique loading conditions. Stress distribution in the peri-implant bone, implants, abutments, and metal framework, as well as implant displacement, was analyzed.
Under vertical loading conditions, Models 2 and 4 demonstrated lower stress values and more balanced load distribution, whereas Models 1 and 3 exhibited higher stress concentrations. In contrast, under oblique loading conditions, Models 1 and 3 showed more favorable stress values compared to Models 2 and 4. Implant displacement values were generally higher in Models 2 and 4. Within the limitations of the present finite element analysis, overall biomechanical response patterns were broadly comparable between the ZAGA Type 1 and Type 3 conditions.
Implant configuration appeared to influence the biomechanical behavior of quad zygomatic implant systems under the tested loading conditions. Models 1 and 3 generally showed a more favorable response under oblique loading, whereas the corresponding models in ZAGA Type 1 and Type 3 exhibited broadly comparable biomechanical patterns.

PMID:
42625457
Bibliographic data and abstract were imported from PubMed on 21 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement