Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Evaluating the Accuracy of Non-Invasive Pulsed-Wave Doppler Echocardiography in Measuring Fetal QT and PR Intervals: A Cross-sectional Study.

Created on 24 Aug 2026

Authors

Feisal Rahimpour, Lida Jarahi, Hasan Birjandi, Mitra Ahmadian, Rasoul Raesi

Published in

Current medical imaging. Aug 03, 2026. Epub Aug 03, 2026.

Abstract

Congenital Long QT Syndrome (LQTS) is a common cause of potentially life-threatening ventricular arrhythmias and sudden cardiac death in infants and children. Fetal Magnetocardiography (fMCG) is available in only a few specialized centers worldwide and offers accurate measurements of the QT and PR intervals. The aim of this study was to assess the diagnostic accuracy of PW Doppler echocardiographic measurement of fetal QT and PR intervals compared with the available normative data for fMCG.
576 pregnant women with singleton pregnancies (16-38 weeks' gestation) were studied in this cross-sectional study between 2022 and 2023 with detailed fetal echocardiograms. Standardized pulsed-wave Doppler techniques were used to measure the PR and QT intervals. Results were compared with published normative data for fMCG, adjusted for gestational age, and were also compared with contemporaneous fMCG in a subset of 42 fetuses.
Mean QT interval (echo) was 270.0 ± 38.8 and mean PR interval was 119.3 ± 16.2. In the paired subset (n = 42), strong agreement was observed (PR ICC = 0.89 [95% CI: 0.81-0.94]; QT ICC = 0.82 [95% CI: 0.72-0.89]), with mean biases of +2.1 ms and +6.8 ms on Bland-Altman analysis, respectively. Sensitivity and specificity for the full cohort for prolonged intervals (> 95th percentile of GA-adjusted fMCG norms) were 85% and 78% (PPV 68%, NPV 90%). There were no clinically significant differences for PR interval or fetal heart rate, and there was no significant correlation between measured intervals and gestational age (p > 0.05).
Pulsed-wave Doppler echocardiography is a reliable method for measuring fetal QT and PR intervals and is in good agreement with fMCG.
It is a practical, non-invasive, and easily accessible substitute for fMCG when it is not available for prenatal screening of cardiac repolarization and conduction abnormalities.

PMID:
42634524
Bibliographic data and abstract were imported from PubMed on 24 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 0
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement