Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Quantification of Fluoride in Serum, Bone, and Teeth in a Murine Model Using Hexamethyldisiloxane-Facilitated Diffusion and Ion-Selective Electrode Measurements.

Created on 29 Aug 2026

Authors

Susanne Brueckner, Juliana Sanches Trevizol, Cameron Fallah, Shohei Yamashita, Motoki Okamoto, Nanako Kuriki, Marilia Afonso Rabelo Buzalaf, Eric T Everett, Maiko Suzuki

Published in

Journal of visualized experiments : JoVE. Issue 234. Aug 28, 2026. Epub Aug 28, 2026.

Abstract

Quantifying fluoride levels in biological tissues is essential for understanding fluoride exposure, metabolism, and toxicity. This protocol describes a sensitive and reproducible method for measuring fluoride ion mass in serum, bone, and teeth using hexamethyldisiloxane (HMDS)‑facilitated diffusion followed by ion‑selective electrode (ISE) analysis. Biological specimens, including serum, femoral bone, and mandibular incisors, are collected from mice exposed to controlled fluoride treatments. Bone and tooth specimens are ashed, milled, and hydrated, while serum is processed directly. Each specimen is transferred to a diffusion dish containing ultrapure water and sealed with a petrolatum‑lined lid bearing sodium hydroxide droplets that serve as fluoride traps. Injection of HMDS‑saturated sulfuric acid initiates fluoride release and diffusion, allowing liberated fluoride ions to be quantitatively captured in the traps. Following overnight diffusion, the fluoride trap droplets are combined into a single sample, acidified to the required pH range, and adjusted to a defined volume for ISE measurement. Calibration diffusion dishes prepared with known fluoride masses generate a standard curve for quantification, and quality control samples verify electrode stability. Representative results from adolescent and mature mice exposed to 0 or 125 ppm fluoride demonstrate the method's ability to detect age‑ and dose‑dependent differences in fluoride levels across serum, bone, and teeth. This protocol provides a robust, calibration‑based approach for quantifying fluoride in diverse biological matrices and is well‑suited for studies investigating fluoride exposure, tissue deposition, and toxicological outcomes in murine models. A key advantage of this method is its ability to accurately quantify fluoride in extremely small specimens, including the 3-5 mg of ash obtained from individual mouse incisors, because the diffusion process concentrates all released fluoride into a measurable sample volume of less than 100 µL.

PMID:
42667223
Bibliographic data and abstract were imported from PubMed on 29 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement