Peak Inspiratory Flow in COPD Patients Treated with Pressurized Metered-Dose Inhalers and Spacers: Implications for Inhaler Selection. A Multicenter Cross-Sectional Study.

Created on 30 Aug 2026

Authors

Lara Bravo Quiroga, Jose Miguel González-Moro Rodríguez, Francisco Javier Álvarez-Gutiérrez, Krasimira Baynova, Mariam de la Poza Abad, Jose Luis Izquierdo-Alonso

Published in

International journal of chronic obstructive pulmonary disease. Volume 21. Pages 621909. Epub Aug 25, 2026.

Abstract

Spacer devices are frequently prescribed with pressurized metered-dose inhalers (pMDIs) in patients with COPD for a variety of clinical and practical reasons, including concerns about inspiratory capacity, inhaler technique, and hand-breath coordination. However, inspiratory flow is rarely measured objectively.
To determine whether COPD patients treated with pMDIs and spacers can generate adequate peak inspiratory flow (PIF) for dry powder inhaler (DPI) use, to evaluate the impact of incomplete exhalation, and to examine patient perceptions of spacer use.
This multicenter, cross-sectional study included 273 clinically stable COPD patients treated with pMDIs and spacers across 70 Spanish centers. PIF was measured with the In-Check Dial at medium-low (R2) and medium-high (R4) resistance under both standard and suboptimal conditions. Patient knowledge, satisfaction, and perceived barriers were evaluated using structured study questionnaires.
Overall, 96.0% of patients achieved a PIF ≥30 L/min at R4, whereas 61.9% reached ≥60 L/min. Incomplete exhalation had only a limited effect on inspiratory performance, with 94.1% of patients maintaining a PIF ≥30 L/min at R4. Lower PIF was associated with greater dyspnea and more severe airflow limitation in bivariate analyses. Spacer prescription was seldom based on objective PIF assessment. Most patients reported practical limitations associated with spacer use and expressed a preference for simpler inhaler devices.
Most COPD patients treated with pMDIs and spacers appear to have sufficient inspiratory capacity to use medium- to high-resistance DPIs. Routine objective assessment of PIF may help optimize individualized inhaler selection and identify patients who could benefit from alternative inhaler devices.

PMID:
42668822
Bibliographic data and abstract were imported from PubMed on 30 Aug 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 9
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement