Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Intravascular hemolysis and clinical outcomes in continuous-flow LVAD patients: A single-center retrospective analysis.

Created on 02 Sep 2026

Authors

Ali Onder Kilic, Cagatay Engin, Tahir Yagdi, Mustafa Ozbaran

Published in

The International journal of artificial organs. Pages 3913988261479983. Sep 02, 2026. Epub Sep 02, 2026.

Abstract

To determine the incidence of intravascular hemolysis in patients implanted with continuous-flow left ventricular assist devices (LVADs), to describe longitudinal changes in hemolysis-related laboratory markers (LDH, total/direct bilirubin, INR), and to assess their diagnostic value for pump thrombosis and cerebrovascular events.
We retrospectively analyzed 100 end-stage heart failure patients (2014-2015). To ensure consistent longitudinal analysis, 59 long-term survivors (42 HeartWare HVAD, 17 HeartMate II) were included. For each patient, a dynamic LDH increase ratio (peak/preoperative baseline) was calculated. The diagnostic performance of the criterion "LDH >250 U/L and ⩾4-fold increase from baseline" was evaluated. Cox regression, ROC analysis, and Kaplan-Meier survival analysis were performed.
During 1-year follow-up, 17 patients experienced thrombotic or cerebrovascular events (8 confirmed pump thrombosis). While absolute LDH values at fixed time points were not discriminative, the dynamic LDH increase ratio was significantly higher in the thrombosis group (p = 0.0102), with an AUC of 0.840. Preoperative LDH was a significant risk factor in Cox regression (HR: 1.005, p = 0.009), reflecting baseline disease severity. The ⩾4-fold LDH increase criterion demonstrated a Negative Predictive Value (NPV) of 97.6%, indicating excellent rule-out performance. No significant difference was found between device types (p > 0.05), supporting a device-independent biomarker dynamic.
Baseline LDH alone is not a reliable predictor of pump thrombosis. In contrast, a ⩾4-fold dynamic rise in LDH relative to the patient's own baseline provides excellent negative predictive value. This dynamic surge serves as a practical, device-independent decision-support tool to rule out pump thrombosis with high confidence in all cf-LVAD patients.

PMID:
42683637
Bibliographic data and abstract were imported from PubMed on 02 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 5
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement