Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Energy-Efficient Peripheral Magnetic Stimulation via Pulse-Shape Optimization using a Dual-Coil Architecture with Monopolar-Like Nerve-Axis Field.

Created on 05 Sep 2026

Authors

Jaeu Park, Yongwoo Kim, Heejae Shin, Minseok Kang, Pritish Nagwade, Sanghoon Lee

Published in

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. Volume PP. Sep 04, 2026. Epub Sep 04, 2026.

Abstract

Peripheral magnetic stimulation (PMS) has emerged as a non-contact neuromodulation technique for rehabilitation and neuroprosthetic applications. However, its practical use remains limited by high power consumption. While coil geometry optimization has been explored, the influence of individual pulse waveform phases on EMG-based functional responses remains largely uncharacterized in PMS. In this study, we present a dual-coil PMS architecture designed to enhance the axial electric-field gradient along the nerve and systematically investigate how pulse waveform parameters influence evoked responses and energy efficiency. Using an in vivo rat common peroneal nerve model, we independently varied the rising phase (RP), maintaining phase (MP), and falling phase (FP) of rectangular current pulses and quantified electromyographic (EMG) responses and per-pulse energy consumption. Decreasing MP reduced EMG amplitude, whereas increasing MP enhanced recruitment until saturation. Under the fixed-current condition, an MP of 100-150 μs provided a practical low-energy range while maintaining a robust EMG-based response. Meanwhile, the energy-normalized response decreased monotonically as RP and FP increased, indicating that shorter transition phases are consistently advantageous from an energy-efficiency standpoint. The timing of the EMG-based functional response was most consistent with initiation by the first induced component, whereas the second component appeared to modulate the final response magnitude. Complementary electromagnetic simulations further showed that the nerve-axis electric-field component generated by the dual-coil configuration partially corresponds to that of a monopolar stimulation profile, providing a structural context for interpreting the observed waveform-dependent responses. Together, these results provide experimentally grounded pulse-design guidelines for energy-constrained PMS systems.

PMID:
42696632
Bibliographic data and abstract were imported from PubMed on 05 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 2
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement