Effect of cement line on radiographic detection accuracy of abutment-prosthesis misfit.

Created on 05 Sep 2026

Authors

Pedro Henrique Hecher Viana, Gabriel Cunha Adiverci, Ingrid Torres de Almeida, Daniela Nascimento Silva, Sergio Lins de-Azevedo-Vaz

Published in

The Journal of prosthetic dentistry. Sep 04, 2026. Epub Sep 04, 2026.

Abstract

Proper prosthetic fit is essential to prevent biofilm accumulation and inflammatory reactions in the peri-implant region. Early detection of misfit at the abutment-prosthesis interface is critical, and periapical radiography has been widely used for this purpose during treatment. However, whether the presence of a cement line influences the accuracy of the radiographic detection of misfit at this interface remains unclear.
To evaluate the influence of a cement line on the detection of abutment-prosthesis misfit of different magnitudes using the bisecting-angle and paralleling periapical radiographic techniques.
A total of 320 periapical radiographs obtained by the bisecting-angle and paralleling techniques were used to analyze 50-, 100-, and 150-µm simulated misfits between the abutment and the prosthetic crown. Three dentists evaluated the images using a 5-point confidence scale (definitely present, probably present, uncertain, probably absent, and definitely absent). Diagnostic accuracy, assessed by the area under the receiver operating characteristic curve (Az), sensitivity, and specificity, were analyzed using Generalized Linear Models (α=.05).
Sensitivity was higher in the cemented groups, particularly for 50 µm (0.87 versus 0.48; P<.001), whereas specificity was higher in the noncemented groups across all techniques and misfit magnitudes (P<.001). Az values were significantly influenced by radiographic technique (P=.005), cementation (P=.035), and misfit magnitude (P<.001), with significant interaction effects between cementation and both technique (P<.001) and magnitude (P=.002).
The presence of a cement line increases sensitivity but reduces specificity, favoring the detection of misfit at the expense of a higher rate of false-positive findings.

PMID:
42697775
Bibliographic data and abstract were imported from PubMed on 05 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 3
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement