Enhancing Inpatient MRI Safety and Workflow Using Standardized MRI Care Level Guidelines and Electronic Medical Record-Integrated Dashboard.

Created on 12 Sep 2026

Authors

Jonathan Garner, Pranay Krishnan, Joseph H Yacoub

Published in

Academic radiology. Sep 11, 2026. Epub Sep 11, 2026.

Abstract

Inpatient magnetic resonance imaging (MRI) presents safety challenges, with deterioration of condition (DOC) as the most serious MRI-related safety event in our health system. To address these risks, standardized MRI Care Level (CL) guidelines and an Electronic Medical Record (EMR)-integrated dashboard were implemented in November, 2022. The CL guidelines stratify patients into three levels, with CL3 patients at highest risk of DOC events. This study evaluates the adoption and impact of MRI Care Level guidelines and an EMR-integrated dashboard on the rate of DOC events in the hospital system.
Inpatient MRI orders and safety events were analyzed from June 01, 2020 to April 30, 2024 across nine hospitals. Descriptive statistics were used to assess adoption rates of the EMR-integrated dashboard and to calculate DOC event rates per 10,000 completed MRI orders before and after implementation.
Five of nine hospitals adopted CL guidelines (participating hospitals); one university-affiliated academic (AH) and four community (CH). 47% of screened orders at participating hospitals were assigned a CL. In AH, 58.5% CL1, 25.1% CL2, 16.4% CL3; in CH, 75.5% CL1, 20.6% CL2, 3.9% CL3. Post-implementation, DOC rates per 10,000 MRIs decreased at participating sites (2.11 to 0.45) but increased at non-participating sites (1.31 to 1.49). Similarly, severe DOC (Cardiopulmonary Resuscitation (CPR)/death) dropped from 0.20 to 0 at participating sites while rising from 0.26 to 0.37 at non-participating hospitals.
Implementation of standardized CL guidelines was followed by a reduction of DOC events at hospitals that have adopted the new MRI Dashboard and safety measures.

PMID:
42728182
Bibliographic data and abstract were imported from PubMed on 12 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 17
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement