Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Model-based motion simulation framework for deep learning-assisted motion correction in dynamic wrist CT.

Created on 12 Sep 2026

Authors

Chunming Gu, Aeden Kayle Davis, Andrew Thoreson, Shengbing Huang, Kevin Treb, Nirusha Lachman, Kristin Zhao, Maryam Sadeghian, Francis Baffour, Taylor P Trentadue, Sanjeev Kakar, Cynthia H McCollough, Shuai Leng, Hao Gong

Published in

Physics in medicine and biology. Sep 11, 2026. Epub Sep 11, 2026.

Abstract

Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted (α=0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference (p>0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55±0.12 to 0.75±0.04 and SSIM from 0.87±0.08 to 0.95±0.03 at bone regions (each p<0.01). In experimental cadaveric scans, LIRS improved from 0.05±0.01 to 0.31±0.17 in marker regions and from 0.58±0.19 to 0.77±0.14 in bone regions (each p<0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement. .

PMID:
42727609
Bibliographic data and abstract were imported from PubMed on 12 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement