Optimal Control-Based RF Pulses Versus Classical Motion-Encoding Strategies for In Vivo Hepatic MR Elastography Across Multiple Excitation Frequencies in Mice: Reproducibility Assessment.

Created on 15 Sep 2026

Authors

Tiffany Bakir-Ageron, Pilar Sango-Solanas, Eric Van Reeth, Denis Grenier, Kevin Tse Ve Koon, Olivier Beuf

Published in

NMR in biomedicine. Volume 39. Issue 10. Pages e70395.

Abstract

This study compared an optimal control (OC)-based motion-encoding approach using radiofrequency (RF) pulses with the conventional motion-encoding gradient (MEG) method for in vivo hepatic magnetic resonance elastography (MRE) across multiple excitation frequencies in mice, evaluating signal quality and temporal reproducibility. Eight healthy C57BL/6 mice, including four males and four females, underwent hepatic MRE at 7T at 300, 500 and 600 Hz using RARE-based sequences: classical MEG-MRE and optimized OC-MRE with GRAPE-designed RF pulses. In both sequences, motion was encoded only along the slice direction. Each mouse was scanned on days 1, 15 and 90. Reconstruction involved phase unwrapping, directional filtering and inversion with the Algebraic Inversion of Differential Equation algorithm to estimate the shear storage modulus ( G ' ) on the manual liver segmentation and on an automatic circular region of interest designed for statistical analyses. Signal-to-noise ratio (SNR), phase-to-noise ratio (PNR) and intra/interanimal reproducibility were quantified using ANOVA, intraclass correlation coefficients (ICC), Bland-Altman analysis and coefficients of variation (CV). OC-MRE provided a mean twofold increase in SNR compared with MEG-MRE (OC/MEG = 1.8-2.1 across frequencies) and higher PNR values. G ' increased with frequency for both methods, consistent with viscoelastic behavior and showed strong intermethod agreement (mean bias < 0.05 kPa; r > 0.96, p < 0.001). Intra-animal reproducibility was moderate at 300 Hz (ICC = 0.31-0.50) and high at 500-600 Hz (ICC > 0.75). No significant temporal changes in hepatic stiffness were observed across sessions. OC-MRE improves signal quality while maintaining quantitative consistency with conventional MEG-MRE. Its short echo time and absence of motion encoding gradients enhance robustness and make it a promising tool for longitudinal small-animal studies and future clinical translation, particularly in scenarios with short transverse relaxation times ( T 2 / T 2 * ) such as those encountered in hepatic iron overload.

PMID:
42742585
Bibliographic data and abstract were imported from PubMed on 15 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement