Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Non-destructive Prediction of Remaining Useful Life for Nickel-Titanium Rotary Files Using Electrochemical Impedance Spectroscopy and Artificial Intelligence.

Created on 21 Sep 2026

Authors

Yueling Ma, Kaige Chen, Yuhao Xu, Yichen Yang, Xiangzhu Wang, Xiaoyu He

Published in

Journal of endodontics. Sep 20, 2026. Epub Sep 20, 2026.

Abstract

Nickel-titanium (NiTi) rotary files are widely used in modern root canal therapy. Although instrument separation is relatively uncommon, sudden fatigue fracture may lead to serious clinical consequences. Current methods are limited to detecting macroscopic defects and cannot quantitatively assess early-stage microscopic fatigue damage. To address this issue, we combined electrochemical impedance spectroscopy (EIS) with artificial intelligence to develop a framework for the non-destructive prediction of the remaining useful life (RUL) of NiTi rotary files.
We conducted EIS monitoring on 94 NiTi rotary files from their pristine state until fatigue fracture, and built a dataset containing 864 valid measurements. We designed a frequency point and sliding window joint optimization strategy to select key features and eliminate feature dimensionality redundancy. Using five-fold cross-validation, we evaluated 18 models: nine traditional machine-learning models, eight conventionally trained deep-learning architectures, and the pretrained tabular foundation model TabPFN; we established a three-level clinical risk-warning system.
Among the evaluated models, CatBoost, a gradient-boosting decision-tree algorithm, achieved the lowest cross-validated mean absolute error (MAE; 0.133 ± 0.015) and a mean three-level risk-classification accuracy of 71.1% ± 2.9%. Furthermore, the joint optimization strategy reduced feature dimensionality by 83.0% without significantly compromising performance. Best-performing traditional machine-learning models outperformed conventionally trained deep-learning architectures and TabPFN on this small tabular dataset.
This study confirms that an EIS- and AI-based non-destructive assessment method enables the quantitative evaluation of the fatigue state of NiTi rotary files prior to fracture, providing a clinically meaningful basis for personalized instrument replacement decisions.

PMID:
42764067
Bibliographic data and abstract were imported from PubMed on 21 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 27
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement