Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Enhanced Visualization of Choroidal Defects in Focal Choroidal Excavation With Near-Infrared Autofluorescence: Multimodal Imaging Study.

Created on 21 Sep 2026

Authors

Yuta Nakanishi, Shin Kadomoto, Tomoaki Sakamoto, Takahiro Kogo, Yuki Muraoka, Masayuki Hata, Akitaka Tsujikawa

Published in

Translational vision science & technology. Volume 15. Issue 9. Pages 10. Sep 01, 2026.

Abstract

To compare the spatial concordance of autofluorescence abnormalities on near-infrared fundus autofluorescence (NIRAF) and short-wavelength fundus autofluorescence (SWAF) with the area of focal choroidal excavation (FCE) defined on en face optical coherence tomography (OCT).
In this retrospective cross-sectional observational study, a 6 × 6-mm en face swept-source OCT image centered on the fovea was used to define the structural FCE area on a choroidal slab. After image registration, areas of abnormal autofluorescence, including hypoautofluorescence and hyperautofluorescence, were delineated on SWAF and NIRAF. Spatial concordance between the en face OCT-defined FCE area and the abnormal autofluorescence areas was evaluated using the Dice similarity coefficient (DSC).
Twenty eyes of 20 patients with conforming-type FCE were included. The mean FCE area was 0.708 ± 0.571 mm2 on en face OCT, 1.174 ± 1.196 mm2 on NIRAF (P = 0.534 vs. en face OCT), and 0.152 ± 0.203 mm2 on SWAF (P < 0.001 vs. en face OCT). Spatial concordance with en face OCT was significantly greater for NIRAF (DSC, 0.654 ± 0.187) than for SWAF (DSC, 0.160 ± 0.214; P < 0.001). NIRAF detected abnormal autofluorescence corresponding to the FCE area in all eyes, whereas SWAF failed to detect any abnormality in six eyes (30%).
FCE-associated abnormalities on NIRAF showed greater spatial concordance with the FCE area defined on en face OCT than those on SWAF.
NIRAF offers a reproducible, noninvasive means of spatially mapping melanin-associated autofluorescence abnormalities, supporting more precise multimodal characterization of FCE.

PMID:
42765795
Bibliographic data and abstract were imported from PubMed on 21 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement