Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.

Created on 21 Sep 2026

Authors

Massimo Baudo, Serge Sicouri, Dimitrios E Magouliotis, Fadi Hage, Rahi Wissam, Scott M Goldman, Eric M Gnall, William A Gray, Sandro Gelsomino, Basel Ramlawi

Published in

Journal of cardiovascular medicine (Hagerstown, Md.). Volume 27. Issue 9. Pages 706-715. Sep 01, 2026. Epub Aug 27, 2026.

Abstract

Balloon-expandable valve (BEV) and self-expanding valve (SEV) platforms have undergone significant technological advancements. This study aimed to compare postoperative outcomes in patients with severe aortic stenosis (AS) treated with transcatheter aortic valve implantation (TAVI) using newer-generation BEV and SEV devices.
We retrospectively analyzed all patients who underwent TAVI for severe native AS at a single center between January 2018 and December 2023. Exclusion criteria included emergency procedures, active endocarditis, prior aortic valve interventions, bicuspid valves, primary aortic regurgitation, non-transfemoral access, concomitant coronary procedures, and use of retracted valves. Bioprosthetic valve dysfunction (BVD) was assessed according to modified Valve Academic Research Consortium 3 (VARC-3) definitions.
Propensity score matching was used to create 354 well balanced pairs. Periprocedural outcomes, including mortality, were comparable between the matched BEV and SEV groups. However, echocardiographic evaluation at discharge revealed significantly higher mean transvalvular gradients (P < 0.001) and peak velocities (P < 0.001) in the BEV group. During follow-up, the SEV group showed a significantly lower incidence of BVD [hazard ratio (HR): 0.64, 95% confidence interval (CI): 0.45-0.91; P = 0.013], particularly regarding higher rates of severe prosthesis-patient mismatch (P = 0.001) and at least moderate structural valve deterioration (P = 0.006). No significant differences were observed in all-cause (HR: 1.18, 95% CI: 0.90-1.56, P = 0.235), or cardiac-related mortality (HR: 1.29, 95% CI: 0.91-1.83, P = 0.157).
Among patients treated with newer-generation transcatheter valves, SEV demonstrated more favorable hemodynamic performance compared with BEV. However, short- and mid-term mortality rates remained similar between the two groups. Longer-term follow-up of randomized trials is needed to confirm these findings.

PMID:
42765779
Bibliographic data and abstract were imported from PubMed on 21 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 10
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement