Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Optimal ROTEM FIBTEM Thresholds for the Identification of Hypofibrinogenemia in Cardiac Surgical Patients: An Analysis of the Influence of Increased Sensitivity on the Rate and Magnitude of False Positives.

Created on 22 Sep 2026

Authors

James Preuss, Clara Forbes, William Weightman, Matthew Linden, Shannon Matzelle, Neville Gibbs

Published in

Journal of cardiothoracic and vascular anesthesia. Aug 29, 2026. Epub Aug 29, 2026.

Abstract

ROTEM Sigma is widely used to identify hypofibrinogenemia (eg, <1.5 g/L) in cardiac surgical patients, with a sensitivity of 0.63 to 0.73 using common FIBTEM A5 (A5) thresholds (eg, A5 <7 mm). This equates to a false negative (FN) rate (1 - sensitivity) of 0.27 to 0.37, meaning that true hypofibrinogenemia may be frequently missed. While sensitivity can be improved by choosing a higher A5 threshold, this results in increased false positives (FP), potentially leading to overtreatment. The influence of higher sensitivity on the rate and magnitude of FPs is unknown, however. This study examined the influence of choosing an A5 threshold with sensitivity ≥0.9 (ie, FN<10%) on the rate and magnitude of FP hypofibrinogenemia in cardiac surgical patients.
Multicenter observational diagnostic accuracy study SETTING: Public and private cardiothoracic surgical centers PARTICIPANTS: 800 cardiac surgical patients INTERVENTIONS: Adjustment of the A5 threshold to achieve sensitivity ≥0.9 for identifying hypofibrinogenemia MEASUREMENTS AND MAIN RESULTS: The A5 threshold to achieve a sensitivity of ≥0.9 to detect Clauss fibrinogen level <1.5 g/L was <10 mm. This was associated with 197 FPs (25%), which had a median Clauss fibrinogen of 1.8 g/L (interquartile range, 1.6-2.0 g/L); 80% were in the range of 1.5 to 2.0 g/L.
In this study, using an A5 with 90% sensitivity to detect Clauss fibrinogen <1.5 g/L (<10 mm) had an FP rate of 25%. However, most of the FPs (80%) were <2.0 g/L. Given the implications of missing hypofibrinogenemia versus the potential unnecessary replacement of fibrinogen mostly within 1.5 to 2.0 g/L, using a higher A5 threshold to improve sensitivity may be a pragmatic option. Nevertheless, these findings require prospective validation.

PMID:
42767884
Bibliographic data and abstract were imported from PubMed on 22 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 18
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement