Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Cerclage for Fracture Reduction is Not Associated with Nonunion in Vancouver B or C Periprosthetic Femur Fractures with Stable Implants: A Multicenter Retrospective Study.

Created on 23 Sep 2026

Authors

Christopher R Leland, Alice W Wong, Carla H Lehle, Robert K Wagner, Phillip T Grisdela, Jacob S Borgida, Arun Aneja, Thuan V Ly, Nishant Suneja, John J Wixted, Paul T Appleton, Edward K Rodriguez, Mitchel B Harris, Michael J Weaver, Arvind G von Keudell, Derek S Stenquist

Published in

Journal of orthopaedic trauma. Sep 23, 2026. Epub Sep 23, 2026.

Abstract

To determine whether circumferential cerclage wiring for fracture reduction during lateral locked plating (LLP) of Vancouver B1 and C periprosthetic femur fractures is associated with nonunion.
Design: Retrospective cohort study.
Three academic Level I trauma centers.
Patients aged >50 years with a Vancouver B1 or C periprosthetic femur fracture (OTA/AO IV.3B1 and IV.3C) who underwent open reduction and internal fixation with a single LLP with or without circumferential cerclage for fracture reduction from 2010-2023 were included.
The primary outcome was nonunion. The association between cerclage use and nonunion was assessed using multivariable logistic regression controlling for age, sex, ASA classification, and Vancouver classification. Secondary outcomes included deep infection and implant revision.
141 patients were included: 102 patients (72%; median age 78 years [IQR, 70-87]; 67% female) were treated with cerclage for fracture reduction and 39 patients (28%; median age 82 years [IQR, 70-89]; 85% female) were not. More patients treated with cerclage sustained a Vancouver B1 than Vancouver C fracture (n=78/102 [76%] vs. n=24/39 [24%]; P<0.001). Plates were longer (16 holes [IQR, 13-18] vs. 14 holes [IQR, 13-16]; P=0.02), stainless steel (n=91/102 [89%] vs. n=27/39 [69%]; P<0.01), and used in neutralization mode (n=96/102 [94%] vs. n=28/39 [72%]; P=0.001) in patients treated with cerclage. Nonunion occurred in 4 patients (4%) treated with cerclage and 4 patients (10%) without (P=0.30). Cerclage use was not associated with developing nonunion in multivariable regression (adjusted odds ratio, 0.3; 95% CI, 0.1-1.8; P=0.19). Infection occurred in 6 patients (6%) treated with cerclage and 0 patients (0%) without (P=0.28). Implant revision occurred in 8 patients (8%) treated with cerclage and 6 patients (15%) without (P=0.31).
While baseline between-group differences were noted in Vancouver classification, the judicious use of circumferential cerclage wiring for fracture reduction and stabilization in Vancouver B and C periprosthetic femur fractures with stable implants was not associated with nonunion. No differences were noted in incidence of deep infection or implant revision following cerclage use in this population.
Therapeutic Level III.

PMID:
42775681
Bibliographic data and abstract were imported from PubMed on 23 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 7
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement