Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Epitope placement tunes CSF tau biomarkers: Comparison of P-tau217 and BD-tau designs.

Created on 24 Sep 2026

Authors

Helena Sophia Gleerup, Christian Sandøe Musaeus, Cristiano Santos, Hlin Kvartsberg, Peter Harrison, Michael Turton, Henrik Zetterberg, Kristian Steen Frederiksen, Steen Gregers Hasselbalch, Anja Hviid Simonsen, Fernando Gonzalez Ortiz

Published in

Molecular neurodegeneration advances. Volume 2. Issue 1. Pages 42. Epub Sep 22, 2026.

Abstract

Measurement of different tau species using immunoassays has proven effective for detecting early Alzheimer's disease (AD) pathology. However, assay performance depends on factors such as the tau form targeted (phosphorylated or non-phosphorylated) and the partner antibody used. Here, we evaluated five different antibody combinations for their ability to differentiate amyloid-positive (Aβ +) from amyloid-negative (Aβ -) individuals in cerebrospinal fluid (CSF).
A total of 290 patients were included in the study grouped by amyloid status. We compared four CSF tau assays designed to separate two axes of assay biology, phosphorylation state and fragment targeting (N-terminal vs mid-domain partner antibodies), to determine how these design choices influence capture of AD pathology.
All CSF tau biomarkers were markedly elevated in the Aβ + group. Phosphorylated tau assays showed larger fold increases (approximately 3-sixfold) compared with non-phosphorylated assays (~ twofold). In linear regression models, all biomarkers were associated with log-transformed pTau217. ROC analyses demonstrated high accuracy for detection of amyloid positivity across assays (AUC range 0.86-0.95). BD-ptau217 achieved the highest AUC (0.95, 95% CI 0.92-0.97) and fold increase in the Aβ + compared to Aβ - .
Our results show that, irrespective of the partner antibody, phosphorylated tau assays are more accurate than assays that also measure non-phosphorylated forms of the protein in differentiating Aβ + from Aβ - individuals. Moreover, among the immunoassays evaluated, BD-pTau217 exhibited a greater fold increase in the Aβ + group than N-terminal pTau217 and Mid-pTau217. Together, these findings underscore the importance of assay configuration for biomarker performance and indicate that BD-pTau217 may offer superior sensitivity for the early identification of AD pathology. Future studies evaluating these assays in plasma are warranted.
The online version contains supplementary material available at https://doi.org/10.1186/s44477-026-00050-z.

PMID:
42780170
Bibliographic data and abstract were imported from PubMed on 24 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 11
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement