Artificial intelligence system for identifying dental implants from intraoral radiographs: A diagnostic accuracy study.

Created on 25 Sep 2026

Authors

Ana Cases-Sánchez, Eva González-Angulo, Alexandra Flesariu-Onu, Carla Fons-Badal, Lucía Fernández-Estevan

Published in

The Journal of prosthetic dentistry. Sep 24, 2026. Epub Sep 24, 2026.

Abstract

Identifying an implant system from radiographic images is essential for managing prosthetic complications but often relies on a clinician's subjective assessment and incomplete patient records. The increasing number of implant systems worldwide complicates accurate recognition and delays treatment procedures.
This study aimed to evaluate the diagnostic performance of a commercially available artificial intelligence software program in identifying different dental implant models from periapical radiographs.
An observational retrospective study was conducted using 720 anonymized periapical radiographs representing 12 implant systems. Each radiograph was uploaded into the MovumStudio implant identification module, and a response was considered correct when the software program identified the implant brand or model as the first option with ≥70% confidence. Descriptive and inferential statistics were performed to assess accuracy, sensitivity, specificity, predictive values, the Cohen kappa coefficient, and the area under the receiver operating characteristic curves (α=.05).
The artificial intelligence system correctly identified 589 of 674 valid intraoral radiographs, achieving an overall accuracy of 87.4% (95% confidence interval, 84.9% to 89.9%) and a Cohen kappa value of 0.864, indicating almost perfect agreement. Sensitivity and specificity were ≥90% for most implant systems, with the area under the receiver operating characteristic curve above 0.90, except for the GMI Frontier system (area under the curve=0.55). The mean response time was 8.42 ±5.96 seconds.
The MovumStudio implant identification module demonstrated high diagnostic accuracy and reliability for recognizing most implant systems from periapical radiographs, offering a rapid, user-independent tool to support clinical decision-making.

PMID:
42786098
Bibliographic data and abstract were imported from PubMed on 25 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 73
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement