Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Effect of R-R interval normalization on frequency domain analysis of heart rate variability during sleep.

Created on 27 Sep 2026

Authors

Jonghyun Hong, Jungmin Koh, Jinyoung Kim, Hyunchan Ryu, Dahye Lee, Ji Ho Choi, Hyun Jae Baek, Heenam Yoon

Published in

Biomedical engineering letters. Volume 16. Issue 5. Pages 1395-1406. Epub Jun 16, 2026.

Abstract

To investigate the effect of R-R interval (RRI) normalization using different scaling factors ([Formula: see text]) on frequency-domain heart rate variability (HRV) parameters during sleep, and determine whether normalization improves the differentiation of sleep stages and enhances the accuracy of slow-wave sleep (SWS) detection. We analyzed the overnight electrocardiogram data of 130 participants. RRIs were normalized using a proposed z-score method with scaling factors (n = 1-4 in [Formula: see text]). Frequency-domain HRV parameters were extracted using raw and normalized RRIs within a 5-min time window shifted by 30 s. HRV parameters were statistically compared across sleep stages (wakefulness, light sleep, SWS, and rapid eye movement sleep), and the SWS detection performance was evaluated using receiver operating characteristic analysis. RRI normalization significantly magnified differences in HRV parameters across sleep stages. HF, which reflects parasympathetic activity, showed a markedly clearer separation between SWS and other stages with normalization (p < 0.05) than with the raw RRI. Consequently, the SWS detection performance was significantly improved. The area under the curve for HF-based SWS detection increased from 0.50 (raw RRI) to a maximum of 0.86 (with [Formula: see text] normalization). HRV parameters derived from normalized RRI reveal the hierarchical organization of autonomic nervous activity across sleep stages, particularly parasympathetic dominance in SWS. This method significantly improves SWS detection accuracy and provides a robust foundation for refined HRV-based sleep monitoring systems. It can be utilized in real-time health monitoring systems to accurately assess sleep stages, stress, and fatigue levels.

PMID:
42800959
Bibliographic data and abstract were imported from PubMed on 27 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement