Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Case Example and Bench Testing of Hydrodynamic Performance and Migration Stability of Various Valve-in-Valve Configurations within a Large-Housing Self-Expanding Pulmonary Valve.

Created on 28 Sep 2026

Authors

Sebastian Góreczny, Damien Kenny

Published in

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. Sep 28, 2026. Epub Sep 28, 2026.

Abstract

Valve-in-valve (ViV) implantation offers a less invasive treatment for degenerated bioprostheses. However, experience with ViV implantation in large self-expanding pulmonary valves is limited, and optimal sizing and stability remain uncertain. A young woman with Noonan syndrome and severe lymphatic disorder underwent implantation of a 36-25 mm VenusP-valve (Venus Medtech) for severe pulmonary regurgitation. Six years later, the valve showed a mild gradient increase and moderate regurgitation (cardiac magnetic resonance regurgitation fraction of 30%). Given her severe lymphatic disorder, repeat percutaneous valve implantation was performed. A second 36-25 mm VenusP-valve was implanted within the existing valve. Incomplete frame apposition was improved with balloon dilation. At 2-year follow-up, there was no systolic gradient and only trace pulmonary regurgitation. Multiple ViV configurations were evaluated in a pulsatile flow system, including one-size-smaller VenusP-valves, a balloon expandable valve, and modified self-expanding valves with flares removed. Effective orifice area (EOA) and regurgitation fraction (RF), including central and paravalvular leakage, were assessed. All configurations showed complete inner-frame expansion and unrestricted leaflet motion, with EOA exceeding predefined acceptance thresholds and RF remaining in the single-digit range. No migration occurred with inner valves one to two sizes smaller than the outer valve under standard conditions, whereas substantially undersized configurations demonstrated instability at higher pressures. ViV implantation within a large self-expanding VenusP-valve was feasible, with favorable function at 2 years. Bench testing demonstrated favorable hydrodynamic performance and supported the stability of appropriately sized inner valves. Further preclinical and clinical evaluation is warranted.

PMID:
42802687
Bibliographic data and abstract were imported from PubMed on 28 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 8
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement