Development and internal validation of a risk-scoring model for gastrointestinal flexible endoscope reprocessing failure: A retrospective observational study.

Created on 28 Sep 2026

Authors

Liangyu Fang, Xiaoxuan Zhou, Meifeng Wu, Yinchuan Xu

Published in

The Journal of international medical research. Volume 54. Issue 9. Pages 3000605261491484. Epub Sep 28, 2026.

Abstract

ObjectiveTo identify risk factors for flexible gastrointestinal endoscope reprocessing failure and develop a practical risk-scoring model for the early identification of high-risk reprocessing cycles.MethodsThis retrospective observational study, conducted from January to December 2025 at three endoscopy centers, included 2744 reprocessing cycles that adhered to WS 507-2016. Internal validation was performed using a split-sample approach, with 70% of the sample used for model derivation and 30% for validation. Predictors were selected using univariable and multivariable logistic regression and converted into an integer-based scoring system, with the optimal cutoff determined using the Youden index. Reporting followed the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis and Strengthening the Reporting of Observational Studies in Epidemiology guidelines, and the study was conducted in accordance with the Declaration of Helsinki.ResultsAmong the 2744 eligible reprocessing cycles, 682 (24.85%) exhibited reprocessing failure. Six independent predictors were identified: brushing personnel, washer-disinfector type, accessory use frequency, prior repair history, time from removal to reprocessing, and staff age. The scoring system, with a range of -2 to 18, achieved an area under the curve of 0.834 (95% confidence interval: 0.804-0.864) in the validation cohort. At a cutoff of ≥10, sensitivity was 0.725, specificity was 0.808, positive predictive value was 0.554, and negative predictive value was 0.899. Calibration was satisfactory based on the Hosmer-Lemeshow test and bootstrap analysis.ConclusionsThe internally validated scoring system enables the early identification of high-risk reprocessing cycles and may support quality improvement efforts. However, external validation is needed to assess its generalizability.

PMID:
42803735
Bibliographic data and abstract were imported from PubMed on 28 Sep 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 15
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement