Hiring in life sciences? Share your open positions with our professional community. Read more Close

Advertisement

Nanopatterned Black Silicon Electrodes for High-Charge-Density Intraspinal Microstimulation.

Created on 01 Oct 2026

Authors

Erik Hakopian, Shan Zhong, Elysia Watkins, Hui Zhong, Alessandro Maggi, Darrin Lee, Charles Liu, Vassilios Christopoulos

Published in

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. Volume PP. Sep 30, 2026. Epub Sep 30, 2026.

Abstract

Restoring motor and sensory function after spinal cord injury (SCI) through intraspinal microstimulation (ISMS) has primarily focused on gray matter targets, while the longitudinally organized axon tracts of spinal cord white matter remain an underexplored route for activating ascending sensory and descending motor pathways. Tract-selective stimulation requires small electrode sites to confine the stimulation field, but miniaturization increases impedance and electrode polarization, limiting the charge that can be delivered from a fixed geometric footprint. To address this challenge, we developed platinum-coated black silicon (BSi-Pt) microelectrodes, in which cryogenically etched black silicon (BSi) nanostructures are conformally coated with platinum to increase electrochemical surface area within a fixed 30×30 μm2 footprint. Relative to thickness-matched, optimized flat Pt controls, BSi-Pt electrodes exhibited a ∼2.2-fold reduction in 1 kHz impedance. Fast- and slow-scan cathodal charge storage capacity (CSCc) values for BSi-Pt were 3.12 mC/cm2 at 250 V/s and 22.3 mC/cm2 at 50 mV/s, corresponding to ∼3.8-and ∼2.3-fold increases, respectively. BSi-Pt electrodes achieved a water-window-based charge injection capacity (CIC) of 0.9 mC/cm2 and a charge injection limit (CIL) of ∼2.2 mC/cm2, defined by the onset of nonlinearity in the input-output response. Finite element analysis (FEA) identified a ground-sheet return configuration that maintained field confinement comparable to a concentric-return configuration while doubling electrode density. Acute proof-of-concept experiments in rat spinal cord (n = 4) evoked propagating activity in the fasciculus gracilis and single-muscle EMG responses from dorsal corticospinal tract stimulation, while continuous pulsing at elevated charge density produced no measurable platinum dissolution. These findings establish BSi-Pt as a manufacturable, CMOS/MEMS-compatible platform for high-density tract-selective ISMS.

PMID:
42814973
Bibliographic data and abstract were imported from PubMed on 01 Oct 2026.

Read full publication at:
Please sign in to see all details.

Advertisement

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 45
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Advertisement